16
ENGLISH
No.
Name.
Description / Action
ERR 01
Temp. sensor
malfunction, cabinet
Replace the temp. sensor.
See Spare Parts, pos. 303.
ERR 02
Temp. sensor
malfunction, exhaust
air
Replace the temp. sensor.
See Spare Parts pos 306
ERR 04
Max. time for the
drying process has
been exceeded
Possible cause - Broken heating elements.
ERR 05
Overheating
Reset. See section ‘Overheating protection’
ERR 08
Clean filter 100
hours
Reset with
START/STOP
for 5 seconds.
Clean filter.
ERR 12
Communication
timeout
Communication error between control panel and
circuit board.
Press the Stop button for 5 seconds to reset an error code.
6.2 Error codes
Capacity:
max 6 - 8 kg laundry
Drainage capacity:
72 g/min (6.5 kg 50% residual moisture)
Electrical connection:
400V 3N AC 50Hz, 10A slow, 10A automatic fuse
Effect:
6,2 kW
Hanging length:
18 metres
Dimensions:
Height 1860 mm
Width 1200 mm
Depth 650 mm
Weight:
145 kg
Sound level:
Airborne noise during full load 57dB (A)
7 Technical data
Summary of Contents for PRO FT 120 FL