background image

5

42445 Avenida Alvarado, Temecula, CA  92590

 (800) 451-9343,  www.nimbuswater.com

This system has been designed for installa

ti

 on by a licensed professional such as a contractor or plumber.  Proper comple

ti

 on of this installa-

ti

  on will require basic familiarity with standard sink plumbing and proper use of common hand and power tools.  Improperly installed systems 

could result in water damage due to leaks or 

fl

 ooding.  Do not use with water that is microbiologically unsafe.

Typical Installa

ti

 on Diagram

A.  Product water storage tank
B. Tank 

shut-o

  valve

C. Tank 

tubing 

D. Air-gap 

faucet

E. Drain 

connec

ti

 on assembly

F. Drain 

tubing

G. Quick-connect 

fi

 

tti

  ng

H.  Product water tubing 
I. Membrane 

desalinator

J. Carbon 

post-

fi

 lter

K. Sediment/carbon 

pre-

fi

 lter

L. Automa

ti

 c shut-o

  valve

M. Inlet 

fi

 

tti

  ng

N.  Feed water tubing
O.  Feed water shut-o

 

A

B

C

D

E

F

G

I

J

K

L

M

N

O

F

H

Summary of Contents for CS-2

Page 1: ... Avenida Alvarado Temecula CA 92590 800 451 9343 www nimbuswater com REV 0507 Nimbus CS 2 Reverse Osmosis System 03 13 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 FAX 951 894 2801 www nimbuswater com ...

Page 2: ...2 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 www nimbuswater com ...

Page 3: ... and must be replaced every 6 12 months Any significant change in performance of the system should be investigated promptly to avoid secondary damage or deterioration to other parts of the system Introduction to the CS 2 Description Replacement Interval RO Membrane Desalinator 12 months Pre filter 6 12 months Post Filter 12 months Tested at 60 psig 4 bar 500ppm TDS municipal water 77 F 25 C Feed W...

Page 4: ...age to the unit due to fire accident negligence act of God or events beyond the control of the Manufacturer are not covered by this warranty Incidental and Consequential Damages The Manufacturer does not assume responsibility for payment of incidental and consequential damages as a result of the failure of this unit to comply with express or implied warranties such as lost time inconvenience damag...

Page 5: ...s Improperly installed systems could result in water damage due to leaks or flooding Do not use with water that is microbiologically unsafe Typical Installation Diagram A Product water storage tank B Tank shut off valve C Tank tubing D Air gap faucet E Drain connection assembly F Drain tubing G Quick connect fitting H Product water tubing I Membrane desalinator J Carbon post filter K Sediment carbo...

Page 6: ...nnection should be hand tightened only Push one end of product tubing into connection 7 Insert tubing and faucet assembly down through the sink hole 8 Position the faucet to the desired handle orientation Slip the slotted washer 1 between the white plastic spacer and the sink Securely hand tighten the mounting nut 9 Connect the 3 8 tubing to the drain saddle assembly using the drain connector nut ...

Page 7: ...e small adhesive foam pad from the small parts bag Fig 2 3 Place the adhesive foam pad on the inside of the the drain saddle front aligning the holes 4 Position the drain saddle on the drain pipe under the sink between the P trap and the sink connection Orient the drain saddle so that the opening is on the side of the drain pipe 5 Using the bolts and hex nuts hand tighten the saddle bracket evenly...

Page 8: ...jaco nut and plastic insert 2 Measure and cut the length of 1 4 tubing long enough to reach from the feed water supply to the inlet Connect the end to the feed inlet on the prefilter using a jaco nut and plastic insert See Fig 5 3 Connect one end of a 3 8 length of tubing to the tank valve Insert the other end firmly into the quick connect cross on the shut off valve 4 Connect the 1 4 tubing from t...

Page 9: ...ridge will release a small amount of carbon fines during the first tankful of flow This flushing procedure will allow any sanitizer or carbon fines to pass from the system 2 Initial tank filling will take approximately one hour based on average feed pressure When the tank is full the water pressure will have risen to the point where the automatic shut off valve inside the system will stop the feed ...

Page 10: ...et and the drain saddle fitting the fitting attached to the sink drain pipe runs downhill to the drain There should be no loops or places where water would not flow out to the drain 5 Feed water valve is open 6 Within one to two hours after initial application of water pressure check again for leaks especially at the tank faucet tubing and connectors These parts will not see full pressure until ap...

Page 11: ...hut off valve 10 The system should be flushed at least once as described above under Section 8 Filter Replacement 1 Close the feed water shut off valve and close the tank shut off valve 2 Open the dispensing faucet to relieve system pressure Close dis pensing faucet when flow has stopped 3 Remove the prefilter housing by turning it clockwise when viewed from above Remove old prefilter from housing an...