4. Important Safety Warning (SAVE THESE INSTRUCTIONS) 

CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free 
of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.) 

CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit 
to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. 

CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave 
ovens, or vacuum cleaners to UPS. 

CAUTION! Do not plug the UPS input into its own output. 

CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-
containing vessels on or near the unit.  

CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power 
supply to properly disable the UPS. 

CAUTION! Do not attach a power strip or surge suppressor to the UPS. 

CAUTION! If the UPS is with metal chassis, for safety purpose, grounding is a must during UPS installation in order to 
reduce leakage current below 3.5A. 

Attention hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still 
may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and 
minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary. 

CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the 
required precautions.  Keep unauthorized personnel away from batteries.  

CAUTION! When replacing the batteries, use the same number and type of batteries. 

CAUTION! Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery. 

CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or 
batteries. Released electrolyte is harmful to the skin and eyes. 

CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

CAUTION! A battery can present a risk of electric shock and high short circuit current. The following precaution should 
be observed before replacing batteries: 

1) 

Remove watches, rings, or other metal objects. 

2) 

Use tools with insulated handles. 

3) 

Wear rubber gloves and boots. 

4) 

Do not lay tools or metal parts on top of batteries. 

5) 

Disconnect charging source prior to connecting or disconnecting batteries terminal. 

 

5. Software Download & Installation (Only for the model with communication port) 

Please follow steps below to download and install monitoring software: 

1. Go to the website 

2. Click ViewPower software icon and then choose your required OS to download the software.  

http://www.nilox.com 

3. Follow the on-screen instructions to install the software. 

4. When your computer restarts, the monitoring software will appear as an orange plug icon located in the system tray, 

near the clock. 

 

Summary of Contents for 17NXGCLI16001

Page 1: ...UPS BUSINESS iPOWER SERIES User Manual...

Page 2: ...f package UPS Unit Quick Guide Power cable only for the IEC type model Please use UPS only in dry place Do not use outdoor Inside UPS you can find a high voltage battery that can determine serious inj...

Page 3: ...pe IEC Type Schuko Type I Schuko Type II South Africa Universal Type Power Switch UPS status LED AC Mode green lighting Battery Mode green flashing Output receptacles Optional USB RJ 11 combinations A...

Page 4: ...s to output receptacles on the rear panel of the UPS Simply turn on the power switch of UPS unit then devices connected to the UPS will be protected by UPS unit Connect Modem Phone Network for Surge P...

Page 5: ...connected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary CAUTION Servicing of batteries should be performed or supervise...

Page 6: ...l The UPS is overload Remove some loads first Before reconnecting equipment please verify that the load matches the UPS capability specified in the specs When power fails back up time is shorten The U...

Page 7: ...uenti componenti Unit UPS Guida rapida Cavo di alimentazione solo per il modello IEC Usate l UPS solo in luoghi asciutti Non usatelo all aperto All interno dell UPS trovate batterie ad alto voltaggio...

Page 8: ...Schuko I Mod Schuko II Mod Sud Africa Modello Universale Interruttore di accensione Spia che indica lo stato dell unit UPS Modalit CA spia verde accesa fissa Modalit batteria spia verde lampeggiante P...

Page 9: ...ufficiente accenderla premendo l apposito interruttore di accensione Collegamento dell unit a un modem telefono o una rete per la protezione contro le sovracorrenti solo per il modello con porta RJ 11...

Page 10: ...superi 3 5 A Tenere sempre presente il possibile rischio di scosse elettriche Anche se l unit stata scollegata dall alimentazione elettrica non possibile escludere la presenza di tensione pericolosa g...

Page 11: ...ore Batterie difettose Sostituire le batterie con modelli dello stesso tipo Unit UPS spenta Premere nuovamente l interruttore di accensione per accendere l unit UPS L allarme continua a rimanere atti...

Page 12: ...dad UPS Gu a r pida Cable de alimentaci n el ctrica s lo en el modelo de tipo IEC Utilice el SAI en un lugar seco No use al aire libre Dentro de la bater as de UPS son de alto voltaje que puede traer...

Page 13: ...IEC Tipo Schuko I Tipo Schuko II Sud frica Tipo Universal Interruptor de encendido LED de estado del UPS Modo AC verde fijo Modo bater a verde intermitente Recept culos de salida Combinaciones USB y R...

Page 14: ...ituados en la parte posterior del UPS Encienda el interruptor de encendido del UPS y los equipos conectados al UPS estar n protegidos por ste Conexi n de m dem tel fono red para la protecci n contra s...

Page 15: ...ra limitar las fugas de corriente a menos de 3 5A Atenci n riesgos de descarga el ctrica Al desconectar la unidad de la red de alimentaci n el ctrica a n puede haber tensiones peligrosas accesibles a...

Page 16: ...horas Fallo de bater a Cambie la bater a por otra del mismo tipo El UPS no est encendido Encienda el UPS pulsando el interruptor de encendido Alarma continua mientras la alimentaci n de red es normal...

Page 17: ...e unsuitable for devices with active PFC The present product has been designed so as to be connected to PCs only any misuse will void warranty immediately ATTENZIONE Questo UPS potrebbe non essere ada...

Reviews: