background image

72 

Original Instructions

Poseidon 2

WARNING! 

Always disconnect 

the electrical plug from the 
socket prior to maintenance or 
cleaning. 
To ensure a long and problem 
free working life, please take 
the following advice:

 Wash off water hose, high 

pressure hose, spray lance 
and accessories before 
mounting.

 Clean the connectors of dust 

and sand. 

 Clean the nozzles.

Any repair should always be 
made in an  authorized work-
shop with original spare parts.

7 Maintenance 

7.1  Cleaning of water inlet  

fi lter

Clean the water inlet fi lter regu-
larly once a month or more fre-
quently according to use. Care-
fully loosen the fi lter with a pair 
of pliers and clean it. Check that 
it is intact before re-mounting it. 

The inlet fi lter must always be 
fi tted inside the water inlet pipe 
to fi lter out various impurities, 
as they will damage the pump 
valves.

CAUTION: 

Failure to fi t the fi lter 

will invalidate the guarantee.

7.2  Cleaning of nozzle 

A clogging up in the nozzle 
causes a pump pressure which 
is too high. This is why cleaning 
is required immediately.
 
1. Stop the machine and dis-

connect the  nozzle. 

2. Clean the nozzle.

 IMPOR-

TANT: 

The cleaning tool (11) 

should only be used when 
the nozzle is detached!

3. Flush the nozzle backwards 

with water.

7.3  Cleaning of machine  

vents

The machine should be kept 
clean so as to let cooling air 

7.4  Greasing of couplings
 

To ensure easy connection and 
that o-rings do not dry up, the 

pass freely through the ma-
chine vents.

couplings should be greased 
regularly.

Summary of Contents for POSEIDON 2

Page 1: ...Operating instructions POSEIDON 2 128330683 b...

Page 2: ...g 3 16 Instruksjonsbok 17 31 Instruktionsbok 32 46 K ytt ohje 47 61 Instruction manual 62 75 Betriebsanleitung 76 92 Manuel d Instructions 93 108 Gebruikershandleiding 109 123 Manuale di istruzioni 12...

Page 3: ...ns without assistance or supervision if their physical sensory or mental capabili ties prevent them from using it safely Children should be su pervised to ensure that they do not play with the applian...

Page 4: ...s damaged it must be re placed by the manufacturer or his service agent or simi larly qualified person in order to avoid a hazard Mains power connection The following should be ob served when connecti...

Page 5: ...injuries 2 1 Application 2 2 Operation elements and model survey See illustration at the end of this manual 1 Start stop switch 2 Water inlet with filter 3 High pressure connection only machines with...

Page 6: ...f hose hook only models without hose reel Mount the hose hook 14 on the handle 2 screws Note the hose hook can be mounted on the front as well as on the back Front position is to be used if the produc...

Page 7: ...lves Caution Failure to fit the filter will invalidate the guarantee 3 5 Mounting of high pressure hose Attach the high pressure hose 4 to the spray handle 7 4 Operating your pressure washer 4 1 Conne...

Page 8: ...he inlet water i e from your own well an addi tional filter should be mounted 1 Let the water run through the water hose before connecting it to the machine to prevent sand and dirt from penetrat ing...

Page 9: ...witch 1 to position I 5 Activate the trigger of the spray handle Always adjust the distance and thus the pressure of the nozzle to the surface which is to be cleaned Do not cover the machine during op...

Page 10: ...etergent and flush with pure water External detergent container 1 Remove the cover with suc tion hose from the detergent container 2 Mount the cover with suction hose on the external deter gent contai...

Page 11: ...chemical product is in direct contact with the dirt Detergents are applied from bottom to top for example on a car bodywork in order to avoid super clean areas where the detergent collects in higher c...

Page 12: ...ne and activate the trigger Let the machine run until no more water runs through the spray handle 3 Stop the machine and un plug Wind the electric cable round the hooks placed on the side of the machi...

Page 13: ...clean it Check that it is intact before re mounting it The inlet filter must always be fitted inside the water inlet pipe to filter out various impurities as they will damage the pump valves CAUTION...

Page 14: ...ee section 7 2 Fuse blows Fuse too small Change to an installation higher than the amp consumption of the machine You may try without the extension cable Machine pulsating Air in inlet hose pump Allow...

Page 15: ...Subject to change as a result of technical advances 10 Main Technical Data Type Poseidon 2 20 Poseidon 2 22 T Poseidon 2 22 XT Poseidon 2 25 XT Poseidon 2 29 Poseidon 2 29 XT Rated pressure bar MPa 69...

Page 16: ...d harmonised standards EN ISO 12100 1 2004 EN ISO 12100 2 2004 EN 60335 2 79 2006 EN 55014 1 2006 EN 55014 2 2001 EN 61000 3 2 2006 Applied national standards and technical specifi cations BS EN 60335...

Page 17: ......

Page 18: ...bardia I 26862 www nilfisk it JAPAN Nilfisk Advance Inc 1 6 6 Kita Shinyokohama Kouhoku Ku Yokohama 223 0059 www nilfisk advance co jp KOREA NIlfisk Advance Korea 471 4 Kumwon B D 2F Gunja Dong Gwangj...

Reviews: