10
Dynamics 440-M/B1
Dynamics 840-M/B1
GB
FOLLOWING WORK
Switch position
0
:
Vacuum cleaner is switched off
(Fig. 11)
.
l
If the vacuum cleaner is not
required for a longer period of
time, pull the mains plug out
of the electrical outlet.
l
Disconnect compressed air
hose
(Fig. 8)
.
MAINTENANCE SCHEDULE
As required
l
Empty tank
l
Replace filter element
Annually
l
A technical dust inspection
must be carried out at least
once a year by the manufac-
turer or an individual com-
missioned by the manufactu-
rer, e.g. for damage to the
separator, tightness of the
appliance, correct function of
the controls.
CARE/MAINTENANCE
IMPORTANT SAFETY
PRECAUTIONS
CAUTION!
Always pull out the mains plug
before performing cleaning or
maintenance work on the
vacuum cleaner.
Only carry out maintenance work
described in these operating
instructions and use only genuine
Wap spare parts.
Do not make any technical
changes to the vacuum cleaner.
CAUTION!
Changes of this type could
endanger your safety.
Please contact Wap Customer
Service or an authorised
workshop for further mainte-
nance and repair work.
EMPTYING TANK
(Fig. 12)
l
Switch off vacuum cleaner by
setting main switch to
0
position.
l
Swing bar (1) of tank lock
upward; tank is lowered.
l
Roll out tank (2).
l
Remove disposal bag, close tightly
and dispose of it in accordance
with legal regulations.
l
Insert new disposal bag.
l
Roll in tank (2). Handle (3)
must face toward front.
l
Swing bar (1) of tank lock
downward; tank is raised and
locked.
Part no. for disposal bag 29727
CHANGING FILTER ELEMENT
l
Pull mains plug.
l
Unlock four quick-lock screws
(1) of cover (2) by turning 90°
and pull off
(Fig. 6)
.
l
Lift off cover (2) and thread out
power cable.
l
Disconnect connection hose of
filter blow-off (3)
(Fig. 13)
.
l
Lift off cover (4) upward and
lay toward rear on vacuum
cleaner
(Fig. 13)
.
l
Pull out filter carrier ring (5)
with filter element (6)
(Fig. 14)
.
l
Lay filter carrier ring (5) upside
down on vacuum cleaner.
l
Screw off hand screw (7).
l
Pull off filter element (6)
upward
(Fig. 15)
.
l
Dispose of used filter element
in accordance with legal
regulations.
Part No. for filter element:
34931.
l
Insert new filter element
centred.
l
Make sure filter blow-off (8)
turns freely
(Fig. 16)
.
l
Fit hand screw and tighten.
l
Remount filter carrier ring (5)
with filter element (6)
(Fig. 14)
.
l
Fit cover (4), making sure that
notches in cover are located
over supports (9) of filter
carrier ring
(Fig. 17)
.
l
Screw on connection hose of
filter blow-off (3) and tighten
(Fig. 17)
.
l
Fit cover (2)
(Fig. 18)
l
Guide power cable (10)
through opening of cover (2)
and under handle (11)
(Fig. 18)
.
l
Move cover (2) into position. No
lines may be visible in area of
exhaust air outlet (3)
(Fig. 6)
.
l
Lock cover by pressing in four
quick-lock screws (1)
(Fig. 6)
.