C411
6
04/2017
VHW200 - VHW201 - VHW210 - VHW211
GB
Power cable
VHW 200
VHW 201
VHW210
VHW211
Type and section
4G - 2,5mm
2
Insulation
450/750V
Minimum external diameter
10 - 15mm
Blower connection cables
VHW 200
VHW 201
VHW210
VHW211
Type and section
4G - 2,5mm
2
Cable clamp size
M25
Temperature
70° C
The indicated temperature is the minimum operating
temperature.
Circuit breaker
The circuit breaker must be chosen according to the current
rating indicated on the vacuum cleaner plate.
Here below there is a list of the suggested ranges for circuit
breakers according to the models:
Model
Circuit breaker
range
VHW200
1,1 ÷ 1,6A
VHW201
VHW210
2,2 ÷ 3,2A
VHW211
Extensions
If an extension cable is used, make sure it is suitable for the
power input and protection degree of the vacuum cleaner.
Minimum section of extension cables:
Maximum length = 20 m
Cable = FROR
VHW 200
VHW 201
VHW210
VHW211
Max power (kW)
1
Minimum section (mm
2
)
1.5
WARNING!
Sockets, plugs, cable clamps, connectors and
installation of the extension cable must maintain the IP
protection degree of the vacuum cleaner, as indicated
on the data plate.
WARNING!
The vacuum cleaners are safe only if equipped with a
circuit breaker protection.
Otherwise there is a risk of electric shock and fire.
WARNING!
The vacuum cleaner’s power socket must be protected
by a differential circuit-breaker with surge current
limitation, that shuts off the power supply when the
current discharged to the ground exceeds 30 mA for
30 msec. or an equivalent protection circuit.
WARNING!
Never spray water on the vacuum cleaner: this could
be dangerous for persons and could short circuit the
power supply.
WARNING!
Comply with the safety regulations governing the
materials for which the vacuum cleaner is used.
Dry applications
[ NOTE ]
The supplied filters and the bag (if applicable) must be
installed correctly.
WARNING!
Comply with the safety regulations governing the
materials for which the vacuum cleaner is used.
Maintenance and repairs
WARNING!
Disconnect the vacuum cleaner from its power source
before cleaning, servicing or replacing parts; the
vacuum cleaner cable plug/terminals must be removed
from the power source.
■
Carry out only the maintenance operations
described in this manual.
■
Use only original spare parts.
■
Do not modify the vacuum cleaner in any way.
Failure to comply with these instructions could
jeopardize your safety. Moreover, such action would
immediately void the EC declaration of conformity/
incorporation issued with the device.
Summary of Contents for VHW200
Page 69: ...C411 2 04 2017 VHW200 VHW201 VHW210 VHW211 3 4 C B A C B A...
Page 70: ...04 2017 3 C411 VHW200 VHW201 VHW210 VHW211 6 5 1 2 3 4 1 7 1 2 3 4 1 1 1...
Page 71: ...C411 4 04 2017 VHW200 VHW201 VHW210 VHW211 8 2 1 4 3 5 9 3 1 2 4 2 1 5 3 4...
Page 72: ...04 2017 5 C411 VHW200 VHW201 VHW210 VHW211 10 11 4 5 6 1 3 2 3 2 1...
Page 73: ...C411 6 04 2017 VHW200 VHW201 VHW210 VHW211 12 13 1 1 2...
Page 75: ...C411 8 04 2017 VHW200 VHW201 VHW210 VHW211 15 E P 3 L 2 L 1 L E P W V U 3 L 2 L 1 L Q1 3 M M1...
Page 76: ...04 2017 9 C411 VHW200 VHW201 VHW210 VHW211...
Page 77: ...C411 10 04 2017 VHW200 VHW201 VHW210 VHW211...
Page 78: ...04 2017 11 C411 VHW200 VHW201 VHW210 VHW211...
Page 79: ......