Troubleshooting
Problem
Cause
Remedy
The vacuum cleaner suddenly stops
Clogged primary filter
Shake the filter. Replace it if necessary.
Clogged vacuum hose
Check the vacuum hose and clean it.
Circuit breaker activation
Check the setting.
Check the motor electrical input. Contact
an authorized after-sales service center if
necessary.
Activation of the level monitoring system.
Emptying of the liquid container.
Dust leaks from the vacuum cleaner
The filter is torn
Replace it with another of identical type.
Inadequate filter
Replace it with another of a suitable category
and check.
Electrostatic current on the vacuum
cleaner
Non existent or inefficient grounding
Check all ground connections. Especially check
the connection at the inlet.