background image

S31N1005P(1)00-11

FILLING UP THE BATTERIES

For filling the batteries follow these instructions:
lift the seat cover 
disconnect the battery power cable and remove the 
batteries from their compartment to make it easier 
to fill them with acid
Remove all the 12 caps and fill each battery cell 
with acid ( sulphuric acid solution density not less 
than 1,270kg/l at 25˚ C) up to the level indicated on 
the batteries.

Wait one hour and recheck the acid level, fill if 
necessary. Let the batteries rest for another hour; 
then proceed with recharging the batteries.

WARNING

: Remove the air venting hole cap from 

the batteries. 

(Fig. 3)

RECHARGING THE BATTERIES

Before installing batteries, which have already been 
filled up, charge them with a suitable battery 
charger. During this 
operation all 
battery caps must 
be open.

CASE 1

: with a 24 

Volt battery charger 
the two 12-Volt 
batteries must be 
connected in series. 

(Fig. B)
NOTE

: the charging 

current must be 
about 2 Ampere.

CASE 2

: with a 12 Volt 

battery charger each 
battery must be 
charged separately. 

(Fig. C)
NOTE

: the charging 

current must be about 2 
Ampere.

After the batteries have been charged, replace the 
caps and clean off any acid that may have spilled on 
the casing. Put the batteries back in the battery 
compartment.
Connect the battery cables being very careful not to 
create contacts between the ( + ) and the ( - ) poles 
of the batteries. Proceed with connecting the 
POSITIVE  POLE  FIRST , then cover it with an 
insulator. Then connect the bridge and insulate the 

poles, the bridge connects the two batteries in 
series.
Last, connect the NEGATIVE POLE and cover it with 
the insulator.

Close the seat cover. 

(Fig. 8)

Each time the batteries are charged, repeat the 
above procedure.

TANK REFUELLING AND OIL CHECKING

Fill the fuel tank with UNLEADED FUEL only.

Check the oil level as specified in the Engine 
Instruction Manual.

SIDE BROOM 
INSTALLATION

Install the brush as 
indicated in the 

figure 

4

, climb onto the 

machine and adjust the 
seat to find the most 
comfortable position.     

(Fig. D)

Now the machine is ready to be used.

STARTING

To start the engine, pull the starter CHOKE knob all 
the way out. 

(item 10 Fig. A)

.

Insert the ignition key into the panel 

(item 6 Fig. A)

 

and turn it clockwise to the ON position. After 
about three seconds the battery voltage will appear 
on the display 

(item 3 Fig. A)

Now turn the key to the  START position.

Once the engine is running, release the ignition key 
and slowly push the start choke knob in. 

(item 10 

Fig. A)

If the engine does not start, repeat the operations 
described above.

Starting the engine will activate the main brush 
and the suction fan.

In order to stop the main broom raise its control 
lever. (item 16 Fig. A)

Sometimes, also when the engine is warm, the 
machine should be started pulling the starter knob.
NOTE: do not try to start the engine for more than 
5 seconds at a time. Subsequent attempts to start 
the engine should be made at intervals of at least 
10 seconds. 

11

FIG. B

FIG. C

FIG. D

Summary of Contents for SR 1005P

Page 1: ...S31N1005P 1 00 11 SWEEPER MANUALE D USO E MANUTENZIONE INSTRUCTION MANUAL FOR USE AND MAINTENANCE MODE D EMPLOI ET D ENTRETIEN BEDIENUNGS UND WARTUNGSANLEITUNG SR 1005P ...

Page 2: ...4 DEUTSCH 25 32 ESPAÑOL 33 40 Model Serial No Power Tot weight Prod No Max axel rear Max axel front Noise level Voltage MADE IN ITALY Nilfisk Advance Italia Località Novella terza 26862 Guardamiglio Italia Tot weight w o battery Type G E Floor cleaning machine S31N1005P 1 00 11 ...

Page 3: ...machine Carefully read the labels on the machine do not cover them for any reason and replace them immediately if they become worn or damaged The machine storage temperature range should be between 25 C and 55 C The machine working temperature is from 0 C to 40 C Humidity range should be between 30 and 95 Do not use the machine in an explosive atmosphere environment Do not use the machine as a tra...

Page 4: ... necessary filled with distilled water Fig 2 In case the batteries are supplied without acid solution they must be filled up The batteries must be filled up in a well ventilated area WARNING the battery acid is corrosive and if it comes in contact with the skin or eyes rinse thoroughly with water and consult a physician TECHNICAL DATA VALUES Engine type Petrol Honda G150 K1 Max power at 3600 RPM 3...

Page 5: ...roceed with connecting the POSITIVE POLE FIRST then cover it with an insulator Then connect the bridge and insulate the poles the bridge connects the two batteries in series Last connect the NEGATIVE POLE and cover it with the insulator Close the seat cover Fig 8 Each time the batteries are charged repeat the above procedure TANK REFUELLING AND OIL CHECKING Fill the fuel tank with UNLEADED FUEL on...

Page 6: ...eed of the machine by setting the speed switch item 9 in Fig A to the turtle symbol Set the switch to the hare symbol for a faster speed as required Turn on the front light if necessary using the button 5 indicated on the figure A To stop the machine quickly press the brake pedal item 12 Fig A The right pedal can also be used as parking brake Press both brake lever controls until the pedal is lock...

Page 7: ...broom in the same orientation figure 15 See also figure G Note before inserting the new broom rotate the adjustment devices to the position that is farthest away from the ground Insert the new brush and make sure that the hub is inserted correctly onto the drive flange Replace the cover and tighten the locking screw SIDE BRUSH ADJUSTMENT AND REPLACEMENT WARNING these operations must be carried out...

Page 8: ...ANCE Given that the user carefully reads the petrol engine Honda G150 K1 Use and maintenance Manual we also provide the following tips Periodically check the engine oil level using the special dip stick Fig 22 for oil filling up use the type specified in the Engine Use and maintenance Manual The engine oil can be changed as follows unscrew the four screws to remove the side hatch as shown in the f...

Page 9: ...room disengaged and battery voltage at about 27 Volt Note The battery life will depend on the level of periodic maintenance checking the electrolyte level and density If the machine is not used for a long time ex 4 to 6 weeks it will be necessary to recharge the batteries to make sure their voltage does not drop below 20 Volts Note unused batteries discharge themselves CHECK UPON DELIVERY TWICE A ...

Page 10: ...acing the electronic board check the continuity of the connection cables between the electronic board and the drive motor check the operation of the two relay on the electronic board Check the operation of the dyna motor and of its carbon brushes For further details see the workshop manual or call a service personnel 306 over temperature on the power electronic board All machine electric functions...

Page 11: ...13 14 15 A B 16 19 22 17 20 18 21 24 23 S31N1005P 1 00 11 ...

Page 12: ...deira 091 228965 Fax 091 228796 SCHWEIZ SUISSE Nilfisk Advance AG Ringstrasse 19 9533 Kirchberg Wil Tel 719 23 52 83 Fax 719 23 84 44 SINGAPORE Nilfisk Advance Pte Ltd 10 Woodlands Loop Singapore 738388 Tel 65 759 9100 Fax 65 759 9133 SVERIGE Nilfisk Advance AB Sjöbjörnsvägen 5 117 67 Stockholm Tel 085 55 944 00 Fax 085 55 944 30 TAIWAN Nilfisk Advance Ltd 1 F No 23 Lane 132 Sec 2 Ta An Road Taipe...