INSTRUCTIONS FOR USE
ENGLISH
9100000383 - SC2000
25
01/2015
DRAINING THE ECOFLEX™ SYSTEM
(For machines with EcoFlex™ system)
Clean the detergent tank following the procedure in the previous section.
To remove residual detergent from the detergent hoses and pump, proceed as follows.
1. To turn on the machine, insert the operator key (41) in its slot on the control panel (3); if the key is already inserted, press the
push-button (42).
2. Press the push-button (43). Check that the detergent quantity indicator (50-G) on the display has at least one segment lit.
3. Press and hold buttons (46) and (47) at the same time until screen (50-N) appears on the display (after approximately 5
seconds).
4.
Release buttons (46) and (47) and wait for the countdown timer on the display to finish and the vacuum system to be activated.
5.
Collect the detergent remained on the floor.
6. Remove the operator key (41).
7. Lift the recovery tank assembly (17), then check that the detergent tank hose (38) is empty, otherwise perform steps 3 to 7
again.
NOTE
The draining cycle lasts about 30 seconds, then the vacuum function automatically turns on, which allows to remove the
detergent remained.
The draining cycle can also be performed with the detergent tank (38) full of water, thus cleaning the system thoroughly.
It is advisable to perform this type of draining to clean the EcoFlex™ system from dirt and deposits if the machine has
not been used/cleaned for a long time.
The draining cycle can also be performed to quickly fill the detergent supply hose when the tank (38) is full but the
system is still empty.
If necessary, the draining cycle can be performed several times in succession.
FUSE CHECK/REPLACEMENT
NOTE
All machine electrical circuits are protected by auto-resettable electronic devices. The safety fuses activates only in case
of serious damage.
It is recommended to have the fuses replaced by qualified personnel only.
Refer to the Service Manual available at any Nilfisk Retailer.
Summary of Contents for SC2000
Page 115: ......