11600400011REVA
9
TROUBLESHOOTING:
CAUTION:
ALWAYS UNPLUG THE MACHINE BEFORE YOU DO ANY TROUBLESHOOTING
NO POWER
TIMER DOES
NOT WORK
CAN NOT
SELECT THE
% OF OZONE
Make sure the power cord is plugged into an operational outlet.
Look at the circuit breaker on the bottom of the machine, to make
sure it has not tripped.
Check the internal safety switch to make sure it is being activiated
when the bottom cover is installed.
CHECK THIS
IF THIS OCCURS --
The digital display has segments missing from some numbers.
The timer
buttons do not change the time display.
The time display does not change as time passes.
>
>
The % button does not work; the amount of ozone light does not
move.
The % button does work, but one or more of the red lights does not
turn on.
CAUTION: BE SURE TO KEEP THE AIR INTAKE FILTER CLEAN
SPECIFICATIONS AND FEATURES:
Output volume:
Maximum Output:
Timer:
Generation Method:
Air Flow:
Deminsions:
Weight:
Features:
Variable
2.2 grams/hour; 6.6 ppm
Digital, 0 to 29 Hours
Patented, high-density ceramic and stainless steel electrodes
2.83 m
3
/minute
55.9 L X 20.3 H X 18 W cm
5.85 kg
•
Rugged construction means reliability
•
No maintainence of plates or UV tubes
•
Over-load protection
WARNING: Use only original Nilfisk spare parts in the ozone machine
Summary of Contents for OZ 1
Page 8: ...11600400011REVA 10 NOTES ...
Page 16: ...11600400011REVA NOTIZEN ...
Page 24: ...11600400011REVA NOTES ...
Page 32: ...11600400011REVA NOTE ...
Page 40: ...11600400011REVA ПРИМЕЧАНИЯ ...
Page 48: ...11600400011REVA ANTECKNINGAR ...
Page 56: ...11600400011REVA NOTAS ...
Page 66: ...11600400011REVA NOTLAR ...