VACUUM SYSTEM
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
VACUUM MOTOR - CARBON BRUSH INSPECTION - 32, 38, 320, 380
1
Drain the solution and recovery tanks and tip them to the sides of the machine.
2
Disconnect the batteries and open the front access door.
3
Remove the large equalizer spring (take note of which hole it is hooked in before removing).
4
See Figure 3. Remove access panel “C”.
FIGURE 3
35
5
Remove plastic cover “D” from the end of one of the vacuum motors.
6
Remove one of the brush holders and remove the carbon brush from the motor.
7
Measure the length of the brush. Replace all of the brushes in both of the motors if it is 3/8 inch (10 mm)
or shorter.
8
Reassemble in reverse order and test for proper operation.
D
C
Front