Nilfisk-Advance C 100.5 User Manual Download Page 13

14

 

Declaration

Manufacturer's name and address or his 
 authorized representative in the Community

Nilfi sk-Advance A/S
Industrikvarteret
9560 Hadsund
Denmark

Name of the person responsible for the 
 technical documentation

Anton Sørensen, General Manager of Technical Operations EAPC

Description of the equipment:
  Equipment name
  Model
  Rated output voltage
  Rated frequency  

High pressure washer
Nilfi sk
C 100.5-5 / C 110.3-5 / C 110.3-5 X-TRA
AC 230-240 V
50 Hz

Measured sound pressure level

78 dB(A)

Guaranteed sound power level

93 dB(A)

Declaration

The equipment refer in this document fulfi ls all the requirements of 
the Directive :

Machine Directive 

2006/42/EC

Low-voltage Directive 

2006/95/EEC

EMC Directive    

 2004/108/EEC

Outdoor Noise Directive  

 2000/14/EC

EN ISO 12100-1, EN ISO 12100-2, EN 60335-2-79
EN 55014-1 (2006), EN 55014-2 (2001), EN 61000-3-2 (2006)

Place and date of the  declaration

Hadsund, September 1, 2008

Signature

9 Main 

Technical 

Data

Type

C 100.5-5

C 110.3-5

C 110.3-5 X-TRA

Rated pressure

bar/
MPa

70/7.0

75/7.5

75/7.5

Permissible pressure

bar/
MPa

max. 100/10.0

max. 110/11.0

max. 110/11.0

Rated flow

l/min

5.3

5.2

5.2

Rated input

kW

1.3

1.4

1.4

Rated voltage

V

 230-240

230-240

230-240

Max. water temperature

°C

40

40

40

Inlet pressure

bar/
MPa

0.15-10/0.015-1.0

0.15-10/0.015-1.0

0.15-10/0.015-1.0

Sound pressure level 

dB(A)

78

78

78

Guaranteed sound power level 

dB(A)

93

93

93

Vibration according to ISO 5349  m/s

2

max. 2.5

max. 2.5

max. 2.5

10 Declaration

Summary of Contents for C 100.5

Page 1: ...Nilfisk C 100 5 Nilfisk C 110 3 C 110 3 X TRA User Manual...

Page 2: ...ildren should be su pervised to ensure that they do not play with the appliance Before starting up your machine please check it carefully for any defects If you find any do not start up your machine a...

Page 3: ...l be made by a certified elec trician and comply with IEC 364 It is recommended that the electric supply to this appli ance should include either a residual current device that will interrupt the supp...

Page 4: ...rsonal injuries 2 2 Operation elements and model survey See illustration at the end of this manual 1 Start stop switch 2 Water inlet with filter 2a 3 High pressure connection 4 High pressure hose 5 El...

Page 5: ...r impurities as these will damage the pump valves Caution Failure to fit the filter will invalidate the guarantee 3 1 Mounting of trolley handle models with trol ley handle 3 3 Mounting of high pres s...

Page 6: ...7 and screw it on Note The spray lance 6 has a built in low pres sure nozzle that can be used for flushing away dirt 2 Attach the nozzle Warning When attaching the Click Clean nozzles the pawl on the...

Page 7: ...uate ventila tion Note If the ma chine is left or not used for 5 min utes it must be switched off on the start stop switch O 1 1 Press the start stop switch O 2 Disconnect the electrical plug from the...

Page 8: ...o storing as follows 1 Stop the machine press the start stop switch O 1 and detach water hose and ac cessory 2 Restart the machine and activate the trigger Let the machine run until no more water runs...

Page 9: ...inlet filter regularly once a month or more frequently according to use Carefully loosen the filter with a screwdriver and clean it Check that it is intact before re mount ing it The inlet filter mus...

Page 10: ...nts The machine should be kept clean so as to let cooling air pass freely through the ma chine vents To ensure an easy connec tion and that o rings do not dry up the couplings should be greased regula...

Page 11: ...own Nozzle partially blocked Clean the nozzle see section 6 2 Fuse blows Fuse too small Change to an installation higher than the amp consumption of the machine You may try without the extension cable...

Page 12: ...kmanship wear and tear as well as misuse are not covered by the guarantee that the directions of this instruction manual have been thoroughly observed that repair has not been carried out or attempted...

Page 13: ...achine Directive 2006 42 EC Low voltage Directive 2006 95 EEC EMC Directive 2004 108 EEC Outdoor Noise Directive 2000 14 EC EN ISO 12100 1 EN ISO 12100 2 EN 60335 2 79 EN 55014 1 2006 EN 55014 2 2001...

Page 14: ......

Page 15: ......

Page 16: ...Nilfisk Advance A S Industrivej 1 DK 9560 Hadsund tel 45 7218 2100...

Reviews: