FORM NO. 56043071 CMAX
™
28/34ST / I-MAX
™
28/32C, BA 750/850ST, BA 750C -
23
SCRUB BRUSH SYSTEM
Yes
No
No
Test for 24/36 volts
at the K1 brush sole-
noid, test point high
current (load) output
wire (WHT) to a bat-
tery ground
Test for 24/36 volts
at the K1 solenoid
Pos. battery load
input wire (RED) to a
battery ground
Repair or replace
wiring
Test for 24/36 Volts
at the main brush
motor feed terminal
block WHT (Pos.)
and BLK (Neg.)
Yes
See Part B scrub
brush control circuit
troubleshooting Part B
Yes
Test for an open
circuit in each brush
motor. Repair or
replace wiring or
motor(s).
No
Test for voltage on
both load wires, WHT
Pos. to a battery
ground and BLK Neg.
to a battery Pos.
Repair or replace
defective wiring.
Scrub brush
motors do not work
(See Figure 1).
SYMPTOM TWO
Scrub Brush Motors Do Not Work
Note: Do all testing with key switch on, scrub on switch activated (scrub deck lowered) and drive paddle activated (pushed Fwd or pulled into Rev).
Note 2: Enter the
Service Test Mode Program
in the Electrical System manual section, for
alternate
machine troubleshooting procedures.
Part A: Scrub Brush Motor Load Circuit Troubleshooting Guide
TROUBLESHOOTING GUIDE (CONTINUED)