4

of the body away from 
ope nings and moving 
parts. Do not put any 
objects into openings 
or use with opening 
blocked. Keep openings 
free of dust, lint, hair, and 
anything else that could re-
 du ce the flow of air.

•  Do not use in outside ar-

eas at low temperature.

•  Do not use to pick up 

flammable or combus-
tible liquids such as 
gasoline, or use in areas 
where they may be pre-
 sent.

•  Do not pick up anything 

that is burning or smok-
ing, such as cigarettes, 
mat ches or hot ashes.

•  Use extra care when 

cleaning on stairs.

•  Do not use unless filters 

are fitted.

•  If the machine is not 

working properly or has 
been dropped, da m-
a ged, left out doors, or 
dropped into water, re-
 turn it to a service center 
or dealer.

•  If foam or liquid es-

capes from the machine, 
switch off immediately.

•  The machine may not be 

used as a water pump. 
The machine is intended 
for vacuuming air and 

water mixtures.

•  Connect the machine to 

a properly earthed mains 
supply. The socket outlet 
and the extension cable 
must have an operative 
protective conductor.

•  Provide for good ven-

tilation at the working 
place.

•  Do not use the machine 

as a ladder or step lad-
der. The machine can tip 
over and become dam-
aged. Danger of injury.

•  Only use the socket out-

let on the machine for 
purposes specified in 
the instructions.

2 Risks 

2.1 Electrical 

components

DANGER

The upper section of the 

machine contains live com-
ponents.
Contact with live compo-
nents leads to serious or 
even fatal injuries.
Never spray water on to 
the upper section of the 
machine.

DANGER

Electric shock due to faulty 
mains connecting lead.
Touching a faulty mains 
connecting lead can result 
in serious or even fatal in-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ATTIX 33-2H PC / IC

Page 1: ...sgef hrliche St ube Entleerung und Wartung einschlie lich Entfernung des Staubbeutels d rfen nur von sachkundigen Personen vorgenommen werden die geeignete pers nliche Schutz ausr stung tragen Nicht e...

Page 2: ...33 2M PC 33 2H PC 33 2M IC 33 2H IC 44 2M PC 44 2H PC 44 2M IC 44 2H IC 33 2M IC Mobile 33 2H IC Mobile 44 2M IC Mobile 44 2H IC Mobile...

Page 3: ...Operating elements 3 1 2 4 5 6 7 8 9 10 13 12 14 11...

Page 4: ...1A 2A M 1 2 1 1 2 1 3 3 4 4 5 5 5 6 6...

Page 5: ...3A M 4A 1 1 2 4 3 5 6 6 1 2 1 4 3 6 5 6...

Page 6: ...5A 21 21 27 27 32 32 36 36 38 38 5A A 2M IC 2H IC 2M PC 2H PC MIN MAX MAX MIN MAX MIN B 2 1 2 7 32 3 6 3 8 3 4 2 1 2M PC 2H PC 2M IC 2H IC...

Page 7: ...6A 6A 1 2...

Page 8: ...7A x4 1 1 2 2 3A 3A 4A 4A 4A 4A 3B 4B 4B...

Page 9: ...8A x2 x2 x4 1B 20 m s 1 3 2...

Page 10: ...2B 3x Push Clean 3B 10 sec In niClean 1 2 3 1 2...

Page 11: ...4B 1C MAX MIN A B 1 2 2 3 4 2 3 4 2 5 5 6 7...

Page 12: ...1D M 2D M 1 2 3 2 4 5 6 7 8 8 2 1 1 4 3 6 7 8 8 5...

Page 13: ...3D 4D M 2 2 3 1 4 5 6 8 9 9 4 6 5 2 3 1 7...

Page 14: ...4D 5D x4 8 7 1 1 2 4 3 5...

Page 15: ...6D 7D 1 2 3 4 5 6 7 1 2 1 3 4 5...

Page 16: ...7D 6 7 8 8...

Page 17: ...e C Connecting electrical appliances 1C Power tool adaption D Maintenance 1D Filter bag replacement 2D Disposal bag replacement 3D Safety filter bag replacement 4D Filter replacement Dust Class M H 5D...

Page 18: ...ordance with the following instructions This machine is intended for commercial use for ex ample in hotels schools hospitals factories shops offices and rental businesses This machine is also suitable...

Page 19: ...to 20 m 1 5 mm2 2 5 mm2 20 to 50 m 2 5 mm2 4 0 mm2 1 6 Guarantee Our general conditions of business are applicable with regard to the guarantee Unauthorised modifications to the appliance the use of i...

Page 20: ...o a service center or dealer If foam or liquid es capes from the machine switch off immediately The machine may not be used as a water pump The machine is intended for vacuuming air and water mixtures...

Page 21: ...t e g magnesium or aluminium dust etc WARNING Using the appliance for as bestos abatement work ac cording to German regulation TRGS 519 To pick up ma terials containing asbestos Dust Class H machines...

Page 22: ...n connect the tubes with the hose handle twist the tubes in order to ensure that they are properly fitted Attach suitable nozzle to the tube Choose nozzle depending on what type of material that is to...

Page 23: ...r is running hold the suction hose shut to reduce the volume flow The LED indicator on front panel will light after approx 1 second The acoustic warning sounds after some additional seconds Set the di...

Page 24: ...g the carboard piece with the rubber membrane through the vacuum inlet Make sure that the rubber membrane is passing past the heightening at the vacuum inlet Safety filter bag check bag to ensure the...

Page 25: ...he ma chine in such a manner that there is no danger for maintenance staff or other persons In the maintenance area Use filtered compulsory ventilation Wear protective clothing Clean the maintenance a...

Page 26: ...nnected load for appliance socket W 2400 2400 2400 2400 1100 1100 1100 1100 1700 1700 750 1750 750 1750 Mains frequency Hz 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 Fuse...

Page 27: ...ilfisk it JAPAN Nilfisk Inc 1 6 6 Kita shinyokohama Kouhoku ku Yokohama 223 0059 Tel 81 45548 2571 www nilfisk com MALAYSIA Nilfisk Sdn Bhd Sd 33 Jalan KIP 10 Taman Perindustrian KIP Sri Damansara 522...