A-12 / ENGLISH
A-12
- 56041640 - Adhancer
™
/ BA 855 TRIO EDS
™
DETERGENT (AXP/EDS) SYSTEM PREPARATION AND USE
NON-DISPOSABLE CARTRIDGE SPECIFIC INSTRUCTIONS:
Fill the detergent cartridge with a maximum of 1.25 gallons (4.73 Liters)
of detergent.
SERVICE NOTE:
Remove the detergent cartridge from the
detergent box prior to
fi
lling to avoid spilling detergent on the machine.
It is recommended that a separate cartridge be used for each detergent
you plan to use. The detergent cartridges have a white decal on them
so you can write the detergent name on each cartridge to avoid mixing
them up. The detergent cartridge has a Magnetic Slider
(CC)
on one end
that needs to be set to the proper dilution ratio according to the dilution
instructions on the manufacturer’s bottle. Slide the Magnet Slider
(CC)
to
the appropriate location on Detergent Dilution Ratio Decal
(DD)
. When
installing a new cartridge, remove the Cap
(AA)
and place the cartridge in
the detergent box. Install the Dry Break Cap
(BB)
as shown.
COMMON INSTRUCTIONS:
The system should be purged of previous detergent when switching
to a different detergent.
SERVICE
NOTE:
Move machine over
fl
oor
drain before purging because a small amount of detergent will be
dispensed in the process.
To Purge When Changing Detergents:
1 Disconnect and remove the detergent cartridge.
2 Turn the Key Switch
(A)
ON and press the Detergent Switch
(F)
and the Solution Switch
(B)
down for at least 2 seconds.
NOTE:
Once activated the purge process takes 10 seconds.
See illustration on next page for Detergent System indicators.
Normally one purge cycle is adequate to purge the system.
To Purge Weekly:
1 Disconnect and remove the detergent cartridge. Install and
connect a Cartridge
fi
lled with clean water.
2 Turn the Key Switch
(A)
ON and press the Detergent Switch
(F)
and the Solution Switch
(B)
down for at least 2 seconds.
NOTE:
Once activated the purge process takes 10 seconds.
See illustration on next page for Detergent System indicators.
Normally one purge cycle is adequate to purge the system.
When the Detergent Cartridge is almost empty a Display Panel
(D)
indicator will come on. This “Low Detergent” indicator will remain on
until you reset the system. Once this indicator comes on you should
be able to simply pour an entire gallon bottle of detergent into the
Cartridge to re
fi
ll without worrying about measuring.
NOTE:
Only
reset the system when the cartridge is full. When switching cartridges,
the “Low Detergent” indicator is only accurate if the replacement
cartridge is at the same level as the cartridge being replaced.
To Reset:
1 Turn the Key Switch
(A)
ON and hold the Detergent Switch
(F)
down for 2 seconds. See illustration on next page for Detergent
System indicators.
DISPOSABLE CARTRIDGE SPECIFIC INSTRUCTIONS:
The standard detergent “Adhancing Agent” comes in a cartridge
without the magnetic slider. The machine will default to the correct
dilution ratio. Remove the Cap
(AA)
and place the cartridge in the
detergent box. Install the Dry Break Cap
(BB)
as shown.