A - 14
SA40 - 56091196
1/2016
INSTRUCTIONS FOR USE
A - ENGLISH
OPERATING THE MACHINE
WARNING!
Be sure you understand the operator controls and their functions.
While on ramps or inclines, avoid sudden stops. Avoid abrupt sharp turns. Use low speed down ramps.
To Scrub...
Follow the instructions in “Preparing the Machine for Use” section of this manual.
1
See Figure 6.
Step onto the Platform
(20)
compressing Operator’s Presence Pedal
(19)
.
NOTE:
Do not press the Go Pedal
(18)
until you are ready to move
the machine.
2
Turn the Key Switch
(A)
ON (I). Wait a few seconds for the start-up sequence to
fi
nish. The graphic display
(F)
will show the information screen
[2]
.
Reference the Battery Charge Level Indicator
(F6)
before proceeding.
3
To transport the machine to the work area,
fi
rst push the Forward Drive Switch
(L)
or Reverse Drive Switch
(N)
to select the direction of travel and then apply
pressure with your foot on the Go Pedal
(18)
.
An audible alert from the horn will sound in reverse. Adjust machine speed by rotating the Speed Adjustment Knob
(K)
clockwise to go faster or
counterclockwise to go slower.
4
Press and hold the Solution Switch
(S)
to pre-wet the
fl
oor, solution will be dispensed at the HIGH rate while the switch is held.
NOTE:
This will help prevent
scarring of the
fl
oor surface when starting to scrub with dry brushes. This can only be done prior to pressing the Scrub ON/OFF Switch
(I)
.
5
Press the Scrub ON/OFF Switch
(I)
. The graphic display
(F)
will change to the scrubbing screen
[1]
. The scrub deck and squeegee will be lowered to the
fl
oor. The scrub, vacuum and solution systems are enabled and will all start when the Go Pedal
(18)
is activated. The scrub parameters are saved after each
use. When the key is turned ON and the scrub button is pressed the scrub parameters (vacuum power, solution
fl
ow rate and scrub pressure setting) will all
be remembered from previous use.
Scrub:
Each press of the Brush Pressure Switch
(P)
will change between STANDARD pressure (
(F3)
bottom box
fi
lled top box empty) and EXTRA pressure
(
(F3)
both bottom and top boxes
fi
lled). The scrub system can only be turned OFF by pressing the Scrub Switch
(I)
.
Solution:
The solution
fl
ow rate can be changed independently of the scrub pressure by pressing the Solution Switch
(S)
. Each press of the switch will cycle
between LOW, MEDIUM, HIGH, OFF and back to LOW. LOW is indicated when
(F2)
displays bottom box
fi
lled, MEDIUM is indicated when
(F2)
displays
bottom and middle boxes
fi
lled, HIGH is indicated when
(F2)
displays all three boxes
fi
lled, and OFF is indicated when
(F2)
displays all three boxes empty.
Vacuum:
The vacuum level can be changed independently. Each press of the Vacuum Switch
(U)
will cycle between LOW, HIGH, OFF and back to LOW.
LOW is indicated when Vacuum Level Bar Graph
(F1)
displays bottom box
fi
lled, HIGH is indicated when
(F1)
displays both bottom and top boxes
fi
lled.
OFF is indicated when
(F1)
displays both bottom and top boxes empty.
NOTE:
To pick up solution without scrubbing, press the Vacuum Switch
(U)
while in
transport mode. This will cause the squeegee to lower and the vac motor to turn ON at the LOW level.
6
Daily Scrub:
Begin scrubbing by driving the machine forward in a straight line at a safe speed and overlap each path by 2-3 inches (50-75 mm). Adjust the
machine speed, scrub pressure and solution
fl
ow when necessary according to the condition of the
fl
oor.
NOTE:
The machine speed can be adjusted by
rotating the Speed Adjustment Knob
(K)
clockwise to go faster or counterclockwise to go slower.
CAUTION!
To avoid damaging the
fl
oor, only start and stop the scrubbing function while the machine is in motion.
7
When scrubbing, check behind the machine occasionally to see that all of the waste water is being picked up. If there is water trailing the machine, you may
be dispensing too much solution, the recovery tank may be full, or the squeegee tool may require adjustment.
8
For extremely dirty
fl
oors, a one-pass scrubbing operation may not be satisfactory and a “double-scrub” operation may be required. This operation is the
same as a one-pass scrubbing except on the
fi
rst pass the squeegee is in the up position. Lift up the squeegee assembly and rotate the double scrub
bracket
(AA)
down, to hold the squeegee off the
fl
oor. This allows the cleaning solution to remain on the
fl
oor to work longer. The
fi
nal pass is made over the
same area, with the squeegee lowered to pick up the accumulated solution.
9
The recovery tank has a shut-off
fl
oat
(14)
that causes a change in pitch in the vac motor. When this
fl
oat is activated, the recovery tank must be emptied.
The machine will not pick up water with the
fl
oat activated.
10 When the operator wants to stop scrubbing:
Press the Scrub Switch
(I)
once. This will automatically stop the scrub brushes and solution
fl
ow and the scrub deck will raise up. The squeegee will raise up
after a brief delay with the scrub deck and the vacuum will stop after a brief time delay (this is to allow any remaining water to be picked up without turning the
vacuum back on) if the vacuum switch is pressed during this time delay the vacuum will turn off.
11 Drive the machine to a designated waste water “DISPOSAL SITE” and empty the recovery tank. To empty, pull the Recovery Tank Drain Hose
(30)
from its
rear storage area, then unscrew the cap (hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled
fl
ow of waste water). The
drain hose can be squeezed to regulate the
fl
ow. Unlatch
(29)
and lift open the Recovery Tank Cover
(13)
to inspect and empty the Debris Catch Tray
(16)
in
the recovery tank. Re
fi
ll the solution tank and continue scrubbing.
NOTE:
Make sure the Recovery Tank Cover
(13)
and the Recovery Tank Drain Hose
(30)
cap are properly seated or the machine will not pick-up water correctly.
When the batteries require recharging the Battery Low Voltage Screen
[3]
will come on. Then the scrub brushes and solution
fl
ow will stop and the scrub deck will
raise up. Once the battery voltage drops below a second cutoff level the squeegee will raise up and the vacuum will stop after a brief delay. Transport the machine
to a service area and recharge the batteries according to the instructions in the Battery section of this manual.