background image

The SVL-2 includes impedance correction circuitry which
protects your receiver or amplifier from low impedance
loads. The circuitry assures that your receiver or amplifier will
see a safe operating load, even when two pairs of 4-ohm
speakers are playing at the same time.

Type of Speaker Wire

For most applications, we recommend you use 16 or 18
gauge stranded copper speaker wire for the SVL-2 connec-
tions. For wiring runs longer than 80 feet, 14 gauge wire is
recommended. Using speaker wire larger than 14 gauge for
the SVL-2 connections is not recommended—the wire may
not fit into the connectors. Never use solid-core, aluminum,
or "Romex" type wire with the SVL-2. When running speaker
wires inside walls, most states and municipalities in the U.S.
specify that you must use a special type of speaker wire.
Usually, the requirement is that the wire has a specific "CL"
fire rating, such as "CL-2" or "CL-3". Consult your Niles deal-
er, building contractor, or local building and inspection
department if unsure about which type of wire is best for
your application.

Avoiding Interference

Speaker wires can act as an antenna for electrical noise.
Locating speaker wires too close to a light dimmer or switch
may cause a "buzzing" or "popping" sound to be heard
thought the speakers. If you must locate the SVL-2 wiring

5

S

P E A K E R

S

E L E C T I O N

/ V

O L U M E

C

O N T R O L

S

Y S T E M

"TECH TIP"

Wire size is

expressed by it's

AWG (American 

Wire Gauge) 

number. The lower

the AWG number,

the larger the wire,

i.e., 12 AWG wire is

physically larger

than 14 AWG.

Summary of Contents for SVL-2

Page 1: ...SVL 2 I N S T A L L A T I O N O P E R A T I O N G U I D E NILES M O D E L SVL 2 SPEAKER SELECTION VOLUME CONTROL SYSTEM SVL 2...

Page 2: ...SVL 2 is individually controlling speaker ON OFF and volume adjustment for two pairs of speakers one pair in the room with the main stereo system and another pair at a remote location The SVL 2 adjus...

Page 3: ...ua tion instead of the usual 20 or 30 dB POP FREE switching between all steps Pre printed Room Labels are included for easy identification of speaker ON OFF buttons Isolated right and left channel gro...

Page 4: ...Match the width of 17 components by combining with another Niles 1 2 width product May be used with 4 6 or 8 ohm speaker systems Ideal for both home and commercial sound installations Only a wire stri...

Page 5: ...plifier Impedance Load As more pairs of speakers are parallel connected to a receiver or amplifier the overall system impedance becomes lower For example if two pairs of 8 ohm speakers are connected i...

Page 6: ...running speaker wires inside walls most states and municipalities in the U S specify that you must use a special type of speaker wire Usually the requirement is that the wire has a specific CL fire ra...

Page 7: ...be sure to always have at least one pair of speakers switched on at all times An alternative is to permanently connect a 150 ohm 5 watt resistor across the tube amplifier s output in parallel with the...

Page 8: ...Corporation Inc Miami Florida USA NILES 12 position volume control provides greater attenuation than conventional 10 position designs Recessed areas for custom room labels Attractive low profile desig...

Page 9: ...abel the wires for future reference See Figure 2 8 S P E A K E R S E L E C T I O N V O L U M E C O N T R O L S Y S T E M Figure 2 Wiring Diagram TUNER 94 9 15 SPEAKER 2 SPEAKER 1 L R AMPLIFIER L R L R...

Page 10: ...er phasing is observed connect the positive terminals on the SVL 2 to the positive terminals on the amplifier and speakers and the negative terminals on the SVL 2 to the negative terminals on the ampl...

Page 11: ...sponds to the speaker pair you wish to play Set it to the ON position 4 Turn on the amplifier or receiver and select as source such as the tuner or CD player 5 Slowly turn up the amplifier or receiver...

Page 12: ...his button activates the SVL 2 s imped ance correction circuitry The circuitry assures that your receiv er or amplifier will see a safe operating load when playing two pairs of speaker simultaneously...

Page 13: ...eached the limit of your amplifier s volume capability and should quickly reduce the volume to avoid damaging your speakers 7 Using the appropriate volume controls on the front of the SVL 2 adjust the...

Page 14: ...lume level of the speakers may vary from room to room This is caused by several factors Two lesser factors are the size of the speaker and its efficiency The largest factor is the physical size of the...

Page 15: ...00 watts channel continuous music power Frequency Response 1 2 dB from 20 Hz to 20 kHz Mounting Table top component Wiring Requirements Individual runs of 2 conductor speaker wire Connectors accommoda...

Page 16: ...0185 NILES 1999 Niles Audio Corporation All rights reserved Because Niles constantly strives to improve the quality of its products Niles reserves the right to change product specifications without n...