Making the IR Sensor/Keypad Connections
• CAUTION: Power to the RVL-6 and amplifier must be disconnected.
• For your convenience, all SENSOR input connectors on the RVL-6 are removable.
• Strip 3/8” of insulation from the end of each wire.
• Tightly twist each wire end until there are no frayed ends.
• Insert each wire into the appropriate hole on the connector terminals using the sensor/keypad wiring con-
vention (see
Figure 9
).
• Tighten the screws which lock the wire into place. Be certain that the polarity labels on the rear of the RVL-6
are precisely followed.
12
V
G
N
D
D
A
T
A
SENSOR/KEYPAD WIRING CONNECTION
Pin 1 = Red (+12V DC) Pin 2 = Bare (Ground) Pin 3 = Black (DATA)
Red
Drain (shield)
Black
MS-1
MS-2
MS-2
MS-2
INTELLIPAD
RP-6
RP-6 / IRR4D+
RP-6 / IRR4D+
RP-6
RP-6
Figure 8 Home running IR sensors/keypads.
Figure 9
11