19
II
N
N F
F R
R A
A R
R E
E D
D
E
E
X
X T
T E
E N
N D
D E
E R
R
-- M
M
A
A II N
N
S
S
Y
Y S
S T
T E
E M
M
U
U
N
N II T
T
•
30
Disconnect All Sensors and Keypads
Observe the IR Test LED.
• IR Test LED is ON or Flickering:
Go to Step 33
• IR Test LED is OFF:
Go to Step 35
•
31
Move the IRP2+ to avoid Electromagnetic
Interference
It is possible that the IRP2+ is receiving electro-
magnetic interference from a nearby television
or other appliance. Move the IRP2+ to another
location and reconnect the power supply.
Observe the IR Test LED.
• IR Test LED is ON or Flickering:
Go to Step 34
• IR Test LED is OFF:
You have EMI in your origi-
nal location. Relocate the IRP2+ according to
the guidelines on Page 5.
•
32
Replace the IRP2+
If you have another IRP2+, exchange it and
retest the system, otherwise, return the IRP2+
to your local Niles dealer for testing.
•
33
Test First Sensor Input
Connect one sensor/keypad to the first Sensor
Input. Observe the IR Test LED.
• IR Test LED Off:
Go to Step 36
• IR Test LED is On or Flickering:
Go to Step 37
•
34
Test Second Sensor Input
A) If you DO NOT have a second sensor/key-
pad, Go to Step 12.
B) If you DO have another sensor/keypad, con-
nect it to the second sensor input. Observe the
IR Test LED.
• IR Test LED is On or Flickering:
Go to Step 37
• IR Test LED Off:
Go to Step 12
•
35
Test for Shorts
A) Verify that all connections at the IRP2+ are
correct. Look for a hair-like filament of wire
between the two contacts.
B) Verify that the sensor/keypad connections
are correct. Look for a hair-like filament of wire
between the two contacts.
C) Disconnect the sensor/keypad cable at both
ends and test the cable itself for shorts. Use an
ohm meter or electrical continuity checker. You
should read an open (Infinite Ohms) between
Red and Bare, Red and Black or Bare and Black.
After testing all connections and cable, observe
the IR test LED.
• IR Test LED is On or Flickering:
Go to Step 38
• IR Test LED is Off:
Congratulations