DATABASE 

-- 

The control unit has been reset to the factory setting 
and requires a renewed default setting. This occurs, 
for example, if software is updated with a new pro-
gram that differs significantly from the old one. 
- Make the desired settings via the menu system 

10  T1 OPEN 

STOP 

Central heating temperature sensor disabled 
- Check connection. Replace sensor if necessary 

11  T1 SHORT 

STOP 

Central heating temperature sensor disabled 
- Check connection. Replace sensor if necessary 

12  T2 OPEN 

STOP 

Domestic water temperature sensor disabled 
- Check connection. Replace sensor if necessary 

13  T2 SHORT 

STOP 

Domestic water temperature sensor disabled 
- Check connection. Replace sensor if necessary 

14  T3 OPEN 

7°C presumed 

Outside temperature sensor disabled 
- Check connection. Replace sensor if necessary 

15  T3 SHORT 

7°C presumed 

Outside temperature sensor disabled 
- Check connection. Replace sensor if necessary 

16  T4 OPEN 

Deactivate room 
control 

Brine temperature sensor disabled 
- Check connection. Replace sensor if necessary 

17  T4 SHORT 

Deactivate room 
control 

Brine temperature sensor disabled 
- Check connection. Replace sensor if necessary 

32  LOW PRS 

Stop compressor  
auxiliary heating 
takes over heat-
ing 

Low pressure alarm. The heat pump will start auto-
matically two minutes after the alarm has 
disappeared.  

33  HIGH PRS 

Stop compressor 
auxiliary heating 
takes over heat-
ing 

High pressure alarm. The heat pump will start auto-
matically 2 minutes after the alarm has disappeared. 
See also Alarm 34. 

34  RESTART 

Stop compressor 
auxiliary heating 
takes over heat-
ing 

Safety shut-off from compressor high pressure. After 
three high-pressure alarms (code 33) within 12 hours, 
alarm 34 is triggered. Alarm 34 includes manual re-
set. The compressor will not restart until you have 
acknowledged Alarm 34 in the Alarm Menu. 

34  RESTART 

Aux heating 
takes over after 5 
mins. 

Safety shut-off from compressor high pressure and 
low pressure 
- Compressor restarts when user acknowledges the 
alarm 

50  FROST 

Circulation 
pumps are start-
ed. 

Temperature for domestic water, central heating or 
room sensor has fallen below 2°C for more than two 
hours. Frost protection function is active 

53  LÆK 

Aux. heatin takes 
over after 5 mins. 

Ground pipe environmental pressure switch 
- Check system for leaks 

54  OVERHEAT 

STOP 

Forward or domestic water overheated to 90°C or 
more 
- Check relays and contacts to compressor and auxil-
iary heating 

70  LEGIO 

-- 

The Legionella function has not been performed with-
in the deadline in two successive weeks. 
- Insufficient heat energy supplied from brine or auxil-
iary loop 

 

Table 1: List of Alarms 

Summary of Contents for LMC 223

Page 1: ...JVP 3 Version 6 00 14 09 2012 Software 1 11 This guidance applies to JVP 3 740023 SW 1 09 Installation and User Guide LMC 223 by Nilan...

Page 2: ...us 15 Main Menus 15 Function Description 20 Heat pump compressor 20 Frequency controlled compressor variable capacity 20 Ground pipe and brine 20 Condenser and heating circulation pump 20 Permitted ar...

Page 3: ...re 3 LMC 223 Control Unit 13 Figure 4 Curve Selection for external temperature compensation 22 Figure 5 Structural ground source pump system diagram 27 Figure 6 Example of layout of ground pipes in a...

Page 4: ...dealer Find your local dealer here www nilan dk forhandlere Control of the system is via a NILAN LMC 223 control unit which offers a wide range of functions for example menu driven control summer wint...

Page 5: ...eating and brine ground source loop Safety valves for central heating and brine ground source loop Low and high pressure cut off switches for compressor Pressure guard brine loop ground pipe mandatory...

Page 6: ...a low temperature in the brine to a higher temperature in the central heating system Circula tion pumps 8 maintain flow in both the ground pipe loop 3 and the central heating floor heating loop 10 Th...

Page 7: ...ntral heating loop and the ground source loop have been ventilated The central heating circuit has an excess flow valve or other circulation which ensures the flow see Figure 5 no 28 Check list for br...

Page 8: ...ol The heat pump is equipped with a low pressure switch which ensures that the brine never be comes so cold that it freezes solid and thus the ground source heat pump s heat exchanger is protected aga...

Page 9: ...ved Page 9 of 33 item 18 and 19 By means of a combined filling and venting tank the brine loop is filled through the filler tap until the loop is compeletely full Figure 5 Structural ground source pum...

Page 10: ...All rights reserved Page 10 of 33 item 13 Duration minimum 1 hour The shutter tap at the cirkulation pump in the brine loop Figure 5 Structural ground source pump system diagram...

Page 11: ...diately if you suspect leakage Water pressure in the central heating loop The water pressure in the central heating loop must initially be inspected as often as several times a day Top up the system w...

Page 12: ...cient to check the filter twice a year Cleaning the dirt filters Switch off the heat pump at the main switch Close the shut off valves on each side of the filter Pull out filter and rinse until clean...

Page 13: ...light in the display is illuminated when the unit is being operated The light switches off after 30 seconds if the unit is not activated by the user The control unit will revert to the start screen s...

Page 14: ...e until the service menu is displayed Press the knob to activate the service menu Turn the knob until the LANGUAGE menu is shown in the display Press the knob The text in the display flashes Turn the...

Page 15: ...user function HEATING has been choice in SELECT in the SERVICE summer winter mode is chosen by an external signal on digital input DI4 Main Menus Parameters in blue text below can be adjusted by auth...

Page 16: ...ST DIFF 40 Compressor start difference shown only when RPM compressor level selected U MIN 25 Minimum voltage to frequency converter shown only when RPM compressor level selected U MAX 100 Maximum vo...

Page 17: ...l heating temperature is 30 C to 45 C By TEMP CTR AMB COMP will restrict the central heating temperature downwards and must therefore be adjusted the curve T HEAT MAX 45 C The maximum permitted setpoi...

Page 18: ...al heat pump system DEFROST CAP 80 Not a function of Geothermal heat pump system NUM HG 0 Not a function of Geothermal heat pump system NUM AIR 0 Not a function of Geothermal heat pump system LAST DE...

Page 19: ...ser function in digital input DI4 NONE DEFROST COOL DELAY HEATING MANUAL Manual activation of relay outlets ACTIVATE NO Activation of manual operation NO YES COMPRESS OFF Start compressor OFF ON AUX O...

Page 20: ...nder 10 If the compressor continues to start stop at short intervals it may be necessary to set a wider neu tral zone in the CENTRAL HEAT NEUTRAL ZONE Menu Ground pipe and brine The brine pump always...

Page 21: ...zone The sys tem thus ensures that the heat pump supplies the greatest share of energy At the same time the user even during extraordinary demand is ensured a well defined comfort The heat pump is de...

Page 22: ...is of these temperatures the central heating temperature is determined by interpolating between the points for a given outside temperature see Figure 4 For outside temperatures under 20 C and over 20...

Page 23: ...nsors or system components can of course render this protection inef fective When the outside temperature falls below 2 C the central heating circulation pump will start With that any spaces under the...

Page 24: ...ting too slowly Possible causes 1 Dirt filter in the central heating system is clogged 2 There is air in the central heating system ventilate the system 3 There is insufficient water in the central he...

Page 25: ...und pipes are leaking Check the following 1 Are all cocks open that should be open 2 Is there enough brine in the system Top up if necessary Check 1 2 and correct the fault Acknowledge the alarm by pr...

Page 26: ...essor auxiliary heating takes over heat ing Low pressure alarm The heat pump will start auto matically two minutes after the alarm has disappeared 33 HIGH PRS W Stop compressor auxiliary heating takes...

Page 27: ...All rights reserved Page 27 of 33 Installation Figure 5 Structural ground source pump system diagram...

Page 28: ...ith software version 1 10 of LMC223 this works as an external summer winter shift In the controller menu SERVICE SELECT USER FUNK can be select HEATING When HEATING is chosen you make and extreme chan...

Page 29: ...All rights reserved Page 29 of 33 Figure 6 Example of layout of ground pipes in a collector Figure 7 Example of layout of ground pipes with collection inside footing...

Page 30: ...lling them with brine Calculate pumping time for filling the system at an established pumping rate It will not take less than the calculated pumping time to fill the system with brine Prevent air from...

Page 31: ...pe N A Brine concentration N A The brine concentrationen freezing temperature registered 20 C til 18 C N A C The brine is properly mixed prior to filling of the circuit The brine cicuit is purge of ai...

Page 32: ...s mounted correctly and has correct opening pressure The is a bypass which ensures a sufficient flow through the condenser eliminates HP cut out The circulation pump must be dimensioned for the specif...

Page 33: ...case a remote running signal from the heat sys tem is used connection must be made and heat pump controller configured for this Supplementing electrical heating element is acti vated if required after...

Reviews: