Subject to alterations
Page 7 of 34
Figur 3: Sketch of Compact Polar Køl Sol EK 3/9
The unit must be installed and leveled on a firm, vibration-free surface. There should be at least
10mm clearance to walls or other permanent installations. Although the unit itself is practically
noise and vibration free, care must be taken to prevent any vibration from being propagated to ad-
joining parts of the building.
The rear angular slide bar of the base frame of the Compact Polar Køl Sol EK 3/9 can be removed
in order to make it possible to push the unit towards the wall to hide water connections etc.
It is important that the condensation outlet of the Compact Polar Køl Sol EK 3/9 be connected to a
drain. The unit is supplied complete with water trap. The outlet should be led frost-free with steady
decline to the nearest drain. The safety valve overflow must also be led to a drain.
If Compact Polar Køl Sol EK 3/9 is enclosed by any covering, it must be possible to remove the
covering easily.