You can read off current operating data for the ventilation unit. This will allow you to check that the unit operates satisfactorily and to
identify the cause of potential alarms.
>Show data
> Compact P
> Operating state
Description:
Shows in which operating setting the ventilation unit is running.
> Bypass
Description:
Shows whether the bypass damper is open or closed.
> Anode
Description:
Shows whether the anode is in working order. If faulty, it must
be replaced.
> T1 Outdoor air
Description:
Shows the outdoor temperature before the pre-heating ele
-
ment.
> T2 Supply air
Description:
Shows the supply air temperature.
> T4 Discharge
Description:
Shows the discharge air temperature in the exchanger.
> T5 Condenser
Description:
Shows the condenser temperature.
> T6 Evaporator
Description:
Shows the evaporator temperature/discharge air temperature.
> T10 Extract air/Room
Description:
Shows the current room temperature measured in the extract
air.
> T11 Top hot water
Description:
Shows the current temperature in the top of the hot water tank.
Controls the supplementary electric heating.
> T12 Bottom hot water
Description:
Shows the current temperature at the bottom of the hot water
tank. Controls the heat pump.
> Humidity
Description:
Shows the current humidity level in the dwelling.
> CO
2
level
Description:
Shows the current CO
2
level in the dwelling (only if installed).
> Supply air fan
Description:
Shows the current fan speed level of the supply air fan.
> Extract air fan
Description:
Shows the current fan speed level of the extract air fan.
> Unit information
Description:
Press for further information about the ventilation unit.
> Unit type
Description:
Shows what type of ventilation unit it is.
> Software version
Description:
Shows the software version of the ventilation unit.
> Panel software
Description:
Shows the software version of the control panel.
> AIR
> Status
Description:
Shows in which operating setting the GEO is running.
> Anode SHW tank
Description:
Shows whether the anode is in working order if an SHW tank has
been installed. If faulty, the anode must be replaced.
> T16 Return flow heating
Description:
Shows the current temperature of the return flow from the
central heating.
> T17 Supply flow heating
Description:
Shows the current temperature of the supply flow to the cen
-
tral heating.
> T18 Buffer tank temperature
Description:
Shows the current temperature of the supply flow to the buffer
tank.
> T20 Outdoor temperature
Description:
Shows the outdoor temperature measured in outdoor unit.
> T21 SHW top temperature
Description:
Shows the current temperature in the top of the SHW tank (only
if installed). Controls the supplementary electric heating.
> T22 SHW bottom tempera
-
ture
Description:
Shows the current temperature at the bottom of the SHW tank
(only if installed). Controls the heat pump.
> T23 Evaporator temperature
Description:
Shows the current evaporator temperature.
> T35 Pressure pipe tempera
-
ture
Description:
Shows the temperature in the pressure pipe.