background image

USER MANUAL

CTS602 LIGHT

 BY NILAN

Comfort 252 / 302 Top / Polar (English)

Version 3.00 - 07.01.2019

Summary of Contents for Comfort 200 Top

Page 1: ...USER MANUAL CTS602 LIGHT BY NILAN Comfort 252 302 Top Polar English Version 3 00 07 01 2019...

Page 2: ...control 8 Maintenance 9 Water trap 9 Filter replacement 9 The exchanger 9 Illustration of filter change 10 User settings Ventilation settings 12 Stop the unit 12 Alarm 12 Show data 13 Date Time 14 Wee...

Page 3: ...rised electrician to rectify the error CAUTION Always disconnect the power supply to the unit before opening the unit doors for instance for installation inspection cleaning and filter change Disposal...

Page 4: ...umidity 3 Shows the CO2 level in the house provided the unit is equipped with a CO2sensor 4 Shows the current fan speed level 5 Shows user selection and week program if these are activated If the unit...

Page 5: ...d The desired room temperature can be adjusted by pressing the up or down arrows followed by the cancel icon bottom left or the accept icon bottom right If you select the option of current fan speed l...

Page 6: ...ar If you select the symbol a description of the warning or the alarm will be displayed The warning or the alarm can be reset by selecting Clear Alarm A warning indicates that something requires atten...

Page 7: ...Settings menu overview The settings menu is constructed to make it easy to navigate through Comfort 252 302 Top Polar English BY NILAN 7...

Page 8: ...that automatically adjusts to the requirements of the family or the building By means of the integral humidity sensor the control system calculates the average level for the previous 24 hours The aver...

Page 9: ...ularly and filled with water especially in the summer when the risk of the water trap drying out is highest Filter replacement The purpose of the filters is to protect the fans and the heat exchanger...

Page 10: ...unit 4 It is advisable that you vacuum the filter chambers for potential dirt and dust 5 Remove the filter sheet from the filter frame 6 Keeping the smooth side facing downwards place the new filter...

Page 11: ...Comfort 252 302 Top Polar English BY NILAN 11...

Page 12: ...read warnings and alarms in the Alarm menu It is likewise possible to reset warnings and alarms in this menu When a warning or an alarm has been triggered an icon appears on the main screen Alarm Alar...

Page 13: ...T8 Outdoor air Description Shows the outdoor temperature before reaching the pre heating element T9 Water heating element Description Shows the temperature in the water after heating element Air humi...

Page 14: ...me in the display Date Time Year Description Select Year in the panel and then select the correct year Month Description Select Month in the panel and then select the correct month Day Description Sel...

Page 15: ...red room temperature here Function 2 Under each function you can set time temperature and fan speed level Start time Settings Standard setting Description Hours and minutes 8 00 Set the time for the p...

Page 16: ...vel 3 Level 4 Off Level 1 Select the desired fan speed level here Temperatures Settings Standard setting Description 5 40 C 22 C Set the desired room temperature here Functions 5 and 6 Settings Standa...

Page 17: ...perature an after heating element must be installed An after heating element allows you to control the supply air temperature regardless of the outdoor temperature An external electrical or water afte...

Page 18: ...growth in the bathroom is reduced and the bathroom mirror will rarely steam up The humidity control system follows the average air humidity level measured over the previous 24 hours In this way the s...

Page 19: ...to high fan speed level Normal CO2 level Settings Standard setting Description 400 750 ppm 600 ppm Here you indicate the CO2 level at which the unit is to switch to normal control Air exchange Low hu...

Page 20: ...can be connected via digital input and adjustment in the filter menu Air filter Filter alarm Settings Standard setting Description Filter monitor 30 60 90 180 360 monitor 70 days 90 days The number of...

Page 21: ...eat recovery Min supply air winter Settings Standard setting Description 14 22 C 16 C Here you can set the minimum supply air temperature that the unit should provide in the winter Only effective with...

Page 22: ...Language The unit is factory set to Danish language You can change the texts to other languages Language Danish Description Select the desired language on the panel 22...

Page 23: ...heating element could not reach 20 C within 6 min Check for adequate insulation around the water heating element and its connections Reset alarm 8 Frost thermostat triggered Temperature sensors Only o...

Page 24: ...d and adjusted if necessary Reset alarm 22 Info Error in air temperature It is impossible to heat the supply air as desired only applicable if you have an after heating element The after heating eleme...

Page 25: ...Product data Declaration of compliance Comfort 252 302 Top Polar English BY NILAN 25...

Page 26: ...ower level LWA 36 dB A Reference flow rate 0 049 m3 s 177 1 m3 h Reference pressure difference 50 Pa SPI 0 17 W m3 h Central demand control 0 85 Maximum internal leakage 1 5 Maximum external leakage 2...

Page 27: ...A Reference flow rate 0 067 m3 s 177 1 m3 h Reference pressure difference 50 Pa SPI 0 22 W m3 h Central demand control 0 85 Maximum internal leakage 1 5 Maximum external leakage 2 9 Visual filter war...

Page 28: ...87 9798361 maurice nilan ie www nilanireland ie Document no B24_Comfort_252 302 Top_GB Nilan A S disclaims all liability for potential errors and omissions in printed instructions or for loss or damag...