background image

 

5

 

BEFORE OPERATING THE UNIT 

 

1.  Inspect cord and plug for damage. 
2.  Visually inspect the HEPA Filter for damage, punctures or tears. If you are operating in or exhausting into a highly 

sensitive area it is strongly recommended that this unit is independently tested to assure proper filtration 
efficiencies. 

3.  Inspect and tighten HEPA the filter hold down nuts, which may have loosened during transportation of the unit. 

 

 

TRANSPORTING AND STORING UNIT 

 

1.  Always handle this unit with care. Rough handling such as dropping, or tipping over the unit, bouncing around in a 

vehicle, and impact from rolling over or off of curbs, stairs and other platforms, could cause serious damage to 
this unit. 

2.  Always clean and decontaminate unit before storing it. Store this unit indoors in a dry location. 

 

 

TROUBLE SHOOTING 

 

 

PROBLEM 

 

Machine will not start 
 
 
 
 
 
 
 
 
Machine will not run 
continuously 

 

POSSBILE CAUSE 

 
Power cord unplugged 
 
Blown or tripped circuit breaker 
 
 
Tripped thermal protector on 
motor 
 
 
Not enough amperage 
 
 
Extension cord too long or 
inappropriate gauge. 
 

REMEDY 

 

Plug cord into outlet 
 
Replace/reset building fuse or  
breaker 
 
Turn off unit and let cool for 
Approximately 20 minutes, then 
back on. 
 
Use a larger circuit or remove  
other appliances from circuit  
 
Use a 12 gauge extension cord
Maximum length 50’ 

 

 

 

 

 

CLEAN AIR EXHAUST DISCHARGE 

 
This portable air scrubber allows the operator to connect a 12” 
exhaust hose to the unit allowing for remote or controlled exhausting 
and/or to create a controlled negative pressure in a contained area. 
 
Simply connect a 12” hose (#860243) to the 12” exhaust flange 
located on the back/exhaust end of unit and extend the hose to the 
desired area you wish to exhaust to.

Summary of Contents for PS2009

Page 1: ...PORTABLE POLY AIR SCRUBBER MODEL PS2009 INSTRUCTION MANUAL...

Page 2: ...unit has been designed for indoor use only Do not use to exhaust hazardous or explosive materials or vapors IMPORTANT SAFETY INSTRUCTIONS a Do not operate any unit with a damaged cord or plug Discard...

Page 3: ...detrimental and harmful to humans plants or property it is strongly recommended that the units be individually tested prior to their use This is to assure that they are maintaining the efficiency lev...

Page 4: ...be placed in the door frame of the unit Close the hinged door of the unit and snap the latches into the locked position Unit is ready for use See Photo 3 4 An optional Carbon Filter can be used to hel...

Page 5: ...t Store this unit indoors in a dry location TROUBLE SHOOTING PROBLEM Machine will not start Machine will not run continuously POSSBILE CAUSE Power cord unplugged Blown or tripped circuit breaker Tripp...

Page 6: ...BLOWER ASSEMBLY 1 9 860725 LATCH 2 10 860724 HANDLE 4 11 862243 FIXED WHEEL 2 12 862244 LOCKING CASTER 2 13 860941 CORD STRAIN RELIEF 1 14 520010 ELECTRICAL CORD 1 15 860402 PS CONTROL PANEL 1 16 861...

Page 7: ...CONTROL PANEL PS2009 WIRING DIAGRAM PC NO PART NO PART NAME QTY 1 861853 THREE WAY SWITCH 1 2 860699 FILTER MONITOR GAUGE 1 3 861854 CIRCUIT BREAKER 1 4 860954 HOUR METER 1 5 860721 GAUGE RELIEF BARB...

Page 8: ...r refund the purchase price of any such defective goods This warranty does not apply to normal wear and tear neglect misuse abuse or incorrect installation If any other replacement parts filters or at...