7.4.2 Repeater can not communicate in Power-ON status
1. The power is on but there is a signal fluctuation or a flash signal. The phone call cannot be made/received.
It shall be caused by the insufficient isolation between outdoor and indoor antennas.
Please take the following measures:
- Firstly check whether the alarm LED lights. The light may indicate the isolation is insufficient.
- Secondly adjust the antennas’ directions or locations or enlarge distance between them.
- Thirdly reduce the repeater’s gain by ATT DIP if the above listed methods don’t work.
The following measures can also be helpful:
- Use the roof of the building to enlarge isolation (Please try to place the outdoor antenna and indoor
antenna on different floors).
- Use some obstacles (Such as walls).
2. The repeater’s power is on but the phone cannot get connected to the network and still can not
communicate.
Reason 1:
There are loose or wrong connections in the repeater system.
Solution:
Please try to fasten the connections between different parts of the system.
Reason 2:
The signals received by outdoor antenna of other operators nearby are too strong. (For example,
the other operators’ signals are 10 dB stronger than the needed signals.)
Solution 1:
Change the direction of the outdoor antenna or its installation position, so that the gap of signal
strength is reduced between operators.
Solution 2:
Use barriers (like buildings and walls) to block signals from other operators.
Summary of Contents for LCD600-GSM+4G