JAA80251-R.3723.A
- A 2・AF-S 24-70/2.8G -
GMR unit
Connect the GMR-FPCs to the connectors of the main PCB.
�
Connect the GMR-FPCs to the
connector, and lock them.
Lock
Lock
Adhesive: Screw lock
GMR base plate
Tape#197
Tape#196
TA-0017(3×8)
A
Tape#196
TA-0017(3×8)
Based on the reference position, fix the GMR-FPC with the tape (#196).
Attach [#196] so that its upper part protrudes from the edge of the GMR base plate by 1mm as
below. Then push [#196] from above with the fingers.
�
Caution: Do NOT attach [#196] at the closer position to the GMR sensor than [#197].
1-mm protrusion from the edge
of the GMR base plate.
Position the GMR-FPC towards the direction of the arrow.
Attach [#196] so that part of it protrudes from the edge of the GMR base plate by 1mm as below.
Then push [#196] from above with the fingers.
�
�
1-mm protrusion from the edge of the
GMR base plate.
Caution: The tape [#196] must NOT touch the below
"
A
"
area of the FPC.
INC