background image

 

nv 

Niko

 sa    Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 760 14 70 — fax +32 3 777 71 20 — e-mail: [email protected] — www.niko.be 

PM119-099R07062

65-220

Congratulations on your purchase of this product from the Niko dimmer 
range. 

1. LEGAL WARNINGS

- Read the complete manual before attempting installation and activating 

the system.

- The installation has to be carried out by a qualified person and in compli-

ance with the statutory regulations.

- This user manual has to be handed over to the user. It has to be included 

in the electrical installation file and has to be passed on to any new own-
ers. Additional copies are available on the Niko website or via the support 
service.

- During installation, the following has to be taken into account (not limited 

to list below):

  - The statutory laws, standards and regulations;
  - The state of the art technique at the moment of installation;
  - This user manual, which must be read within the scope of each specific 

installation, only states general regulations;

  - The rules of proper workmanship
- In case of questions, you can consult Niko’s support service or contact 

a registered control organisation.

  Support Belgium: 

Support Slovakia:

  +32 3 760 14 82 

+421 263 825 155

  website : http://www.niko.be 

e-mail: [email protected]

  e-mail: [email protected]
In case of a defect, you can return your product to a registered Niko 
wholesaler, together with a clear description of your complaint (Conditions 
of use, stated defect…).

2. DESCRIPTION

The 65-220 is an innovative link between dimmer and user. Each dim circuit can 
consist of several dimmers connected in parallel. This way, the total available 
power is virtually unlimited. The system allows for an unknown flexibility:
- the number of control points is unlimited
- every dimmer can be controlled in a different way
- every dimmer can react in a different way, to be determined by the 
user
- installation and programming are very simple
To illustrate the flexibility of the system, it is useful to have a closer look at 
the different components of a dimmer:

1. Push buttons

This term indicates any control element the 65-220 accepts as contact: 
- push buttons (normally open, potentialfree contact 07-000)
- relays
- pulses (open collector systems, TTL output)...

2. Preset

A preset is a preset light intensity. Min. and max. light levels can be preset 
in a ‘preset’. The settings are made by means of trimpotentiometers.

3. Trimpotentiometers

Small potentiometers that are soldered directly on the printed circuit board. 
The setting is carried out by means of a miniature screwdriver.  

4. Dia

Same meaning as preset (see 2): also called light atmosphere, …

3. OPERATION AND USE

To the 65-220, one or more N.O. contacts can be connected. This is the 
only part you are confronted with as a user and is often reduced to a simple 
push button. The control transforms these N.O. contacts into 1/10V analog 
signals that control the dimmer. One dim circuit can be controlled by several 
push buttons. You can assign a different function to every push button. 
You can also control the system via every N.O. contact and potentialfree 
equivalent of a push button, as e.g. relais, pulses (TTL min. 50ms), infrared 
receiver (see user manual infrared transmitter). 
Different push buttons can retrieve the same function in parallel from 
different places (see fig. S165200). You can extend the available capac-
ity per circuit by connecting the different dimmers in parallel. Choosing 
the function (the way in which the dimmer reacts to a command) is very 
simple: it suffices to choose the connection terminal that corresponds to 
the chosen function. 

3.1. Checking the connections
terminal nr.  usage

0/10V control output to dimmer

common 0V (for both in- and outputs)

+24V power supply for interface (supplied by the dim-

mer)

increase light intensity (as long as contact closed)

decrease light intensity (as long as contact closed)

switch off (brief press suffices)

retrieve preset 5 (brief press suffices)

retrieve preset 4

retrieve preset 3

10 

retrieve preset 2

11 

retrieve preset 1

trimmer  

usage

speed control: controls the fade in/fade out 

 

time between every action

light intensity control preset 1

light intensity control preset 2

light intensity control preset 3

light intensity control preset 4

light intensity control preset 5

Note: 

an unlimited number of push buttons can be connected in parallel. 

Turn left: min. light level (to completely OFF)
Turn right: max. light level (to completely ON)
Turn left: min. speed = longest time
Turn right: max. speed = shortest time
The level adjustment can be viewed in real time by connecting the terminal 
to the common during the regulation of the trimmer (= contact closed).
If you bridge the resp. terminals, any non-contradictory combination of 
functions can be retrieved simultaneously. E.g.: if you connect the terminals 
of the resp. interfaces to the same push button, preset 2 can be retrieved for 
different circuits simultaneously. This allows for dividing e.g. large conference 
rooms into different zones. Every zone can then be controlled separately or 
every combination of joined zones can be controlled together. 

3.2. Start up

Preset 1 is automatically retrieved when starting up or after a power cut. It 
is therefore advisable to set the highest light level in preset 1. If you do not 
wish to use this function, set preset 1 to 0%.

3.3. Cable sections

The system is galvanically isolated from the mains. A control cable with a 
0,14mm

2

 section suffices. The max. voltage is 30V. The distance between 

the different components (dimmers, interfaces, push buttons) is max. 1500m 
if a 2,5mm

2

 control cable is used.

3.4. Usage warnings

- The dimmers are never electrically seperated from the mains by controlling 

the push buttons. All components, incl. the lamps, are always live, even 
if the lights are ‘off’.

- Safety is only guaranteed if the control is powered by an insulated low 

voltage power supply (max. 24V).  This essential condition is fulfilled if this 
power supply is branched off on the resp. terminal of a Silicon dimmer.

- The 65-220 control can never be connected to the mains. A safe distance 

to and isolation from the mains cables is required.

4. GUARANTEE PROVISIONS

- Period of guarantee: 2 years from date of delivery. The delivery date is 

the invoice date of purchase of the product by the consumer. If there is 
no invoice, the date of production applies.

- The consumer is obliged to inform Niko in writing about the defect, within 

two months after stating the defect.

- In case of a failure to conform, the consumer has the right to a repair or 

replacement (decided by Niko) free of charge.

- Niko cannot be held liable for a defect or damage as a result of an incorrect 

installation, improper or careless use or wrong usage or transformation 
of the goods.

- The compulsory regulations of the national legislation concerning the 

sales of consumer goods and the protection of the consumers in the 
countries where Niko sells, directly or via sister or daughter companies, 
chain stores, distributors, agents or permanent sales representatives, 
take priority over the rules and regulations mentioned above.

C O N T R O L S

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

a

 b

 c

 d

 e

 f

A

B

D

C

E

F

L1

L3

N

L2

3 x 400V~ + N

65-110

65-110

65-220

OV (COM)

+24V

UP

DOWN

OFF

P5

P4

P3

P2

P1

1

2

3

4

5

6

7

8

9

10

11

OUT

65-220

OV (COM)

+24V

UP

DOWN

OFF

P5

P4

P3

P2

P1

1

2

3

4

5

6

7

8

9

10

11

OUT

65-220

OV (COM)

+24V

UP

DOWN

OFF

P5

P4

P3

P2

P1

1

2

3

4

5

6

7

8

9

10

11

OUT

S165220

2

11

10

9

8

7

6

5

4

B

U

TT

O

N

S

2

11

10

9

8

7

6

5

4

B

U

TT

O

N

S

R,L,C

1

2

3

4

L

L

N

N

N

N

COM

/ 0-10V /1-10V

DC

    65-410

select

prog

  input

  mode

   max

    min

I

U

T

0-10V

1-10V

230V~ 50Hz

R,L,C

100...1400W

100...1400VA  

100...1400VA

ε

ta = 35°C

65-410

67-710

Max

1400VA

R,L,C

1

2

3

4

L

L

N

N

N

N

COM

/ 0-10V /1-10V

DC

    65-410

select

prog

  input

  mode

   max

    min

I

U

T

0-10V

1-10V

230V~ 50Hz

R,L,C

100...1400W

100...1400VA  

100...1400VA

ε

ta = 35°C

65-410

Max

1400VA

R,L,C

1

2

3

4

L

L

N

N

N

N

COM

/ 0-10V /1-10V

DC

    65-410

select

prog

  input

  mode

   max

    min

I

U

T

0-10V

1-10V

230V~ 50Hz

R,L,C

100...1400W

100...1400VA  

100...1400VA

ε

ta = 35°C

65-410

Max

1400VA

67-710

230V ~ 50Hz

L

N

VDC+

DALI+ COMMON-

BRIDGE

PROTECTION

Reviews: