20
10-901
General operation
Action
Feedback
Meaning feedback
1 Opening door
- enter the coden 1x beep + green LED lights (± 3s) Code ok, door open
- press
#
3x beep + red LED lights (± 3s)
Code not OK!
3x beep + red LED lights (± 120s) 3x false code, code keyboard blocked for 120s.
2 controlling the light switch relay (bus power supply 10-801 or 10-802)
- press
#
1x beep
light switch relay controlled
Programming:
Enter the appliance’s programming mode to modify the settings.
Feedback during programming
Action
Optical feedback
Acoustic feedback
Enter programming mode code keyboard The LED blinks (1Hz) green.
long beep
Enter programming mode bus power supply The LED blinks (2Hz) green for 120s. no feedback
Key combination ok
LED blinks (1Hz) green, because in
programming mode.
1x beep
Key combination not ok
3x beep
Activating programming mode
1. press
✱
2. enter master code
3. press
#
master code = max. 6 digits
master code = 123456
Settings
Action(s)
Possible settings
Fabric
settings
1 Programming the user code(s)
Note: max. 10 user codes can be programmed!
enter the following key combination:
✱
0
#
code (= 1-10)
#
code
#
code
#
code = position 1-10 for the user codes
code = max. 6 digits (= user code)
111
2 (De)activating the relay contact (R-contact) for a user code
enter the following key combination:
✱
1
#
code (= 1-10)
#
R
#
R = 0;
R contact does not switch
R = 1;
R contact does switch
R = 1
3 Defining the sent command (after inserting a correct code)
enter the following key combination:
✱
2
#
code (=1-10)
#
P
#
P = 0;
standard door open command with
external unit address of code keyboard for
controlling the door opener of power sup-
plies 10-801, 10-802 and 10-806
P = 1;
control function 1 (+ own serial number)
P = 6;
control function “code (= 1-10)” (+ own
serial number)
P = 7;
not sending a command
P = 0
external
unit ad-
dress = 0
4 Erasing the programmed data for one of the 10 positions (codes)
enter the following key combination:
✱
3
#
code (1-10)
#
EN