background image

ASSEMBLY INSTRUCTIONS

Prior to assembly, compare the main diagram with your PiMag

Aqua Pour

Gravity Water System, and make sure all the components are present. 
1. Locate the filter cartridge (G) and remove from packaging. 

• Remove and discard the lids that cover the top and bottom of the cartridge. 

• Rinse the filter cartridge in cold, clean water for 5-10 minutes. Keep flushing

until the water flowing through the cartridge is completely clear. 

IMPORTANT:

Do not use hot water. Do not use soap or detergent to clean

the cartridge. 

2. Wash the inside of the fill tank (C) and supply tank (I) with water and a mild

detergent or soap. 

IMPORTANT:

Do not use hot water. Do not use a scrubber sponge or paper

towels. Rinse both tanks very thoroughly. 
• Place the supply tank on the base (O). 
• The water tap (K) is supplied with two ring seals — one is to be placed 

on each side of the supply tank wall. Unscrew the magnetic tube (N) from the
tap and remove the magnetic tube ring seal (M). 

• Push the tap ring seal (L) all the way up against the end of the tap. Insert the

tap through the hole in the water supply tank. Push the magnetic tube ring seal
onto the end of the tap pipe, inside the supply tank. Screw on the magnetic
tube and tighten until both ring seals are snug against the wall of the tank.

3. Rinse the mineral stones (J) thoroughly under running cold

water. Set on towel to air dry.  

4. Place the mineral stones in the bottom of the water supply tank (I). 

• Arrange the stones in a circle so that they will not touch the

filter when it is inserted. 

• Place the water tank cover (H) on the supply tank. This is the

cover that has a large hole in the middle.

5. Fit the filter ring seal (F) onto the threaded end of the filter

cartridge. 
• Screw the filter plate (E) to the top of the filter cartridge. 
• Insert the filter cartridge and plate in the water tank cover. 
• Fit the plate ring seal (D) inside the plate opening. 
• Place water fill tank on top of this opening, on plate ring seal.

6. Rinse the microsponge filter (B) or ceramic filter (P) thoroughly in cold, clean

running water. 

IMPORTANT:

Do not use hot water. Do not use soap or

detergent to clean the microsponge or ceramic filter. 
• When the microsponge is still wet, press it in place inside

the opening in the top of the fill tank. (To install the ceramic
filter instead, refer to the instructions on its use.)

7. Pour water into the fill tank (use COLD municipally treated tap

water only and fill using a pitcher or other container).
• When the tank is full, press several times on the microsponge

filter or lift an edge of the sponge to drive out any air bubbles.

8. Water will flow from the fill tank through the filters and into the supply tank. 

• When the supply tank is full, drain off and discard the first tankful of water. In

some areas, the filtered water may retain a bitter taste, which will require this
step to be repeated one or more times. 

• Your Nikken PiMag Aqua Pour Gravity Water System is now ready for use.

Fill the water fill tank again and place the cover (A) on the unit.

(1)

(2)

(3)

(4b)

(5)

(6b)

(7)

(6a)

(4a)

-5-

Summary of Contents for Pimag Aqua Pour

Page 1: ...OPERATING MANUAL GUIDE D UTILISATION MANUAL DE USO PIMAG TM AQUA POUR TM gravity water system syst me d eau gravitationnel sistema de agua y gravedad...

Page 2: ...his filter contains activated carbon It further reduces the amounts of contaminants by natural filtration Pi ceramics pi material is added to create PiMag water the water of life Zeolite filter a gran...

Page 3: ...lons 4 000 liters whichever comes first Component life may vary depending on water quality Nikken EPA Establishment No 75805 CA 001 Aqua Pour meets NSF ANSI 42 standards for chlorine reduction as veri...

Page 4: ...LTER PLATE E FILTER RING SEAL F FILTER CARTRIDGE G WATER TANK COVER H WATER SUPPLY TANK I MINERAL STONES J WATER TAP K TAP RING SEAL L MAGNETIC TUBE RING SEAL M MAGNETIC TUBE N BASE O CERAMIC FILTER W...

Page 5: ...the water supply tank I Arrange the stones in a circle so that they will not touch the filter when it is inserted Place the water tank cover H on the supply tank This is the cover that has a large ho...

Page 6: ...upper fill water tank more than halfway Overfilling the tank may cause the unit to overflow MAINTENANCE Keep the PiMag Aqua Pour Gravity Water System away from direct sunlight Hand wash the water tan...

Page 7: ...ement intervals and replace each item at least as often as recommended ITEM DESCRIPTION REPLACED REPLACED REPLACED REPLACED REPLACED REPLACED 1361 FILTER CARTRIDGE 1362 MICROSPONGE PREFILTER 1364 CERA...

Page 8: ...filtre contient du charbon activ Il r duit encore plus les quantit s de contaminants gr ce une filtration naturelle Filtre de z olite La z olite est une substance granuleuse qui fournit une filtratio...

Page 9: ...IT DU FILTRE F CARTOUCHE DE FILTRE G COUVERCLE DU R SERVOIR D EAU H R SERVOIR D APPROVISIONNEMENT D EAU I PIERRES MIN RALES J ROBINET D EAU K JOINT D TANCH IT DU ROBINET L JOINT D TANCH IT DU TUBE MAG...

Page 10: ...que les deux joints d tanch it soient bien serr s contre les parois du r servoir 3 Lavez les pierres min rales abondamment sous l eau courante AVERTISSEMENT N utilisez pas de savon ou de d tergent 4 P...

Page 11: ...N Conservez le Syst me d eau gravitationnel PiMag Aqua Pour de Nikken l abri de la lumi re directe Lavez les r servoirs d eau la main r guli rement une tois par mois environ pour garantir leur propret...

Page 12: ...vie des composants peut varier selon la qualit de l eau Num ro d tablissement EPA de Nikken 75805 CA 001 L Aqua Pour satisfait aux standards NSF ANSI 42 pour la r duction de chlore tel que v rifi et d...

Page 13: ...de l intervalle de remplacement et remplacez chaque composant au moins aussi souvent que recommand ARTICLE DESCRIPTION REMPLAC REMPLAC REMPLAC REMPLAC REMPLAC REMPLAC 1361 CARTOUCHE DE FILTRE 1362 PR...

Page 14: ...para suavizar el agua Filtro de carbono este filtro contiene carbono activado Ayuda a reducir a n m s la concentraci n de contaminantes a trav s de una filtraci n natural Cer mica pi se agrega materia...

Page 15: ...ad del agua N de establecimiento de la Agencia de Protecci n Ambiental EPA de Nikken 75805 CA 001 El Aqua Pour cumple con los est ndares establecidos en la normativa NSF ANSI 42 referente a la reducci...

Page 16: ...DOR DEL FILTRO F CARTUCHO DEL FILTRO G CUBIERTA DEL TANQUE DE AGUA H TANQUE DE AGUA DE SUMINISTRO I PIEDRAS MINERALES J GRIFO K ANILLO SELLADOR DEL GRIFO L ANILLO SELLADOR DE TUBO MAGN TICO M TUBO MAG...

Page 17: ...ormando un c rculo de modo que no toquen el filtro cuando lo coloque Ponga la cubierta del tanque H sobre el tanque de suministro Es la cubierta que tiene un orificio grande en el medio 5 Coloque el a...

Page 18: ...erior de llenado s lo hasta la mitad o menos Si llena demasiado el tanque se puede rebalsar la unidad MANTENIMIENTO Evite exponer el Sistema de agua y gravedad PiMag Aqua Pour a la luz solar directa L...

Page 19: ...alos de reemplazo y reemplace cada elemento al menos con la frecuencia que se recomienda all ART CULO N DESCRIPCI N REEMPLAZADO REEMPLAZADO REEMPLAZADO REEMPLAZADO REEMPLAZADO REEMPLAZADO 1361 CARTUCH...

Page 20: ...ada Corp 6460 Kennedy Road Unit C Mississauga Ontario L5T 2X4 www nikken com 2010 Nikken Inc Printed in Korea Imprim en Cor e Impreso en Corea Reproduction of this printed literature is prohibited Tou...

Reviews: