3 Point measurement gives high accuracy measurement of internal diameter.

FEATURES

S-LINE THREE-POINT INTERNAL MICROMETER

Thank you for purchasing the S-Line THREE-Point Internal Micrometer.

Please read this manual thoroughly before use for proper operation. Ring gauge calibration standard is not included for 

zero-setting, please prepare appropriate ring gauge as required by the instrument

ʼ

s measurement range.

INSTRUCTION MANUAL

Model No. : MCA-*****S / MC-****IPS <combined>

Always wipe measuring surfaces with a cloth to remove any dirt before use.

Do not turn spindle more than 0.5mm above upper measurement range.

If probe tips do not return after Thimble is loosened, please use hand in dust free glove to push in.

This is a precision instrument, handle with care. Do not drop or subject to excessive forces.

Please do not disassemble or modify.

Keep instrument away from direct sunlight or high temperatures such as in a car, or near a stove or heat source.

Remove dust and cutting chips after use and apply rust preventative oil to metallic surfaces. Please keep out of reach of children.

Please do not use organic solvents to clean the body of the instrument.

Keep instrument away from water and oil.

Only use as directed. Improper use may cause accident or injury.

SPECIFICATIONS

PART IDENTIFICATION

READING THE SCALE

Maximum permissible error :

 

4

μ

m

Operating Temperature Range : 15

40

Storage Temperature Range 

0

50



Gauge Head

CAUTION

(Constant Force Mechanism)

Sleeve

Rod

Probe tips

Reference Line

0-Point Adjustment Screw

Thimble

Ratchet Stop 

Thimble Scale

(e.g.) MCA-1620S

Resolution = 0.002mm

Sleeve  Scale Reading

Thimble Scale Reading

Vernier Scale Reading

     

     Reading                      

mm

Sleeve Scale

Thimble Scale

(e.g.) MC-2025IPS

Resolution = 0.005mm

Vernier Scale

16.0  

  .06 

  .006

16.066

Reference Line

Sleeve Scale

Reference Line

Vernier Scale aligns 

at 6 on the Thimble

Read the Thimble Scale at the Reference Line

Sleeve  Scale Reading

Thimble Scale Reading

     

     Reading                      

mm

20.0  

  .015

20.015

Sleeve reading greater than 16

Reference Line past 

the 6

(Ring gauge calibration standard is
 not included.)

Included for use when 

adjusting for wear of 

micrometer screw.

Key

Allen Wrench

:

:

:
:

ACCESSORIES

Adjust Thimble to match 

value of ring gauge

Loosen

Ratchet Stop

Allen Wrench

Thimble moves again

ZERO-POINT SETTING

 Prepare instrument and ring gauge for calibration by cleaning 

measurement head and ring gauge inner diameter with 
appropriate cleaner. 

 Insert the measurement head into the ring gauge and turn 

Spindle until the measuring surfaces make contact with the 
inside of the ring gauge. Continue turning until Ratchet Stop 

clicks

 1~3 times.

 Determine if the micrometer reading from the Spindle Scale 

and Thimble matches the size of the ring gauge calibration 
standard.

 If they do not match, without moving Thimble from position 

set in step 

 above, perform the following procedure.

Use ring gauge appropriate for instrument measuring range.

 Remove any grease and dust 

from the measuring surfaces with 
a clean cloth, such as a lens 
cleaning cloth. Make sure no 
foreign objects are adhered to 
the surfaces.

 Insert the measurement head into 

object to be measured and turn 
Spindle until the measuring 
surfaces make contact with the 
inside diameter. Continue turning 
until Ratchet Stop 

clicks

 1~3 

times.

 Read the measured value 

following the 

Reading the Scale

 

procedure above.

OPERATION

TROUBLESHOOTING

MICROMETER SCREW WEAR ADJUSTMENT

Wear on the micrometer screw in the sleeve will affect accuracy 
of the measurement. Please adjust using the key provide as 
required.

 Remove the Thimble by rotating as shown.

 Insert the Key into the notches in the exposed brass nut.

 Rotate the Key in the clockwise direction a little at a time. 

    (Over-tightening will make the Thimble hard to turn)

 Replace Thimble and then perform the zero-point setting        

 procedure described above.

If issue does not resolve, or if you have any questions, please contact distributor or place of purchase.

Please note, manufacturer is unable to respond to inquires or provide service directly. 

Please contact distributor or place of purchase.

ERROR CONDITION

CORRECTIVE ACTION

Measured value is wrong

Clean measuring surfaces with cloth.
Check to insure zero-point is correct. Please reset zero-point.
If micrometer nut seems worn, please adjust using the above 
procedure.

Probe tips do not return

Please push in by hand in dust free glove.



1)  Tighten the 0-Point Adjustment 

Screw using the supplied Allen 
Wrench to prevent the Thimble 
from turning.

2)  Using the Allen Wrench, loosen 

the screw above the Ratchet Stop 
until the Thimble is able to move 
again. Turn the Thimble to adjust 
the reading to the proper setting.

3) Tighten the screw above the Ratchet Stop, then loosen the 

0-Point Adjustment Screw. Zero-setting is now complete.

Tighten

Thimble

Nut

Sleeve

Remove

Tighten

0-Point 

Adjustment Screw

Allen Wrench

Locking the Thimble

Determine if the scale 

reading matches the 

ring gauge size.

Thimble

Sleeve

Ratchet Stop

Ring gauge 

calibration standard

(e.g.) 20.005mm

Object to be measured

0-Point 

Adjustment Screw

Inse

rt

Key

Measurement

Range

Model No.

Resolution

Weight

Measuring Surface

Material

MCA-0608S
MCA-0810S
MCA-10125S
MCA-12516S
MCA-1620S
MC-2025IPS
MC-2535IPS
MC-3550IPS

  6
  8
10
12.5
16
20
25
35

  8
10
12.5
16
20
25
35
50

95

105
115
140
155
305
325
465

(mm)

(mm)

(g)

Carbide Tip

Alloy Tool Steel

0.002

0.005

Summary of Contents for MCA S Series

Page 1: ...マイクロ メータナッ トが磨耗した 時の調整に使用します キー 六角棒レンチ 測定子を含めた測定部を脱脂し グラスペーパなどで拭き取って 異物が付着していない状態にし てください 測定部を被測定物の内径に入れ ラチェットストップを持って回 します 測定子と被測定物の内 径が接触し ラチェットストップ が カチカチ と1 3回鳴っ たところで停止してください 表面 目盛の読み方 に従って スリーブとシンブルの目盛を読 み取ってください 使 用 方 法 トラブルと対応 マイクロメータナットが磨耗した時の調整 スリーブの内部にあるマイクロメータナットが磨耗して 測定の精度が低くなった場合は付属のキーを使って調整 してください シンブルを回して外してください 真鍮製のナットの切り欠き部分にキーを入れます キーを時計回りに回し少しずつ締めます 締めすぎるとシンブルが回りにくくなります シンブルを組み...

Page 2: ...appropriate cleaner Insert the measurement head into the ring gauge and turn Spindle until the measuring surfaces make contact with the inside of the ring gauge Continue turning until Ratchet Stop clicks 1 3 times Determine if the micrometer reading from the Spindle Scale and Thimble matches the size of the ring gauge calibration standard If they do not match without moving Thimble from position s...

Reviews: