background image

        

PP

        

PP

        

PP

        

PP

PREPARATION FOR USE

Before using the caliper, follow the steps below:

Loosen the lock screw.

Moving the vernier slide with the lock screw tightened may cause excessive force to the slide which will damage the caliper and affect 
accuracy.

Wipe off any dirt, or oil from measuring surfaces and slide.

Contamination of surfaces  may cause measurement error.

Allow the caliper and object to be measured time to reach the same temperature.

A temperature difference between the object to be measured and the caliper may cause measurement error. Allow enough time for the 
temperatures to equilibrate.

Performing an accuracy check.

Jaw Alignment

In closed position, make sure the measuring surfaces on the outside jaws 

align properly and there is no gap (no light should leak past.)

Confirm 

0

 points on scale (see diagram at right)

With jaws closed as in step 

 above, make sure the reading is zero and 

the vernier scale graduations align at the 

0

 and 

39

 positions as shown.

Depth Confirmation

Position caliper on a flat surface for depth measurement. Reading should 
be 

0

 as in step 

 above, with the verier graduations aligned at the 

0

 

and 

39

 positions.

READING THE SCALE

The measured value is determined by reading the main scale, 
and  then  adding  the  Vernier  Scale  reading  as  determined  by 
the position where the vernier and main scale graduations align.

PREVENTING ERRORS

In order to prevent measurement error, please note the following.

AFTER USE CARE, STORAGE NOTES

Material : Stainless Steel

GVC-15KDE

150mm

140g

GVC-20KDE

200mm

0.05mm

200g

GVC-30KDE

300mm

380g

±

0.05mm

±

0.08mm

SPECIFICATIONS

Wipe slide, measuring surfaces, and exterior with a dry 
cloth treated with anti-corrosive oil. When not in use, 
apply anti-corrosive treatment or keep in anti-corrosive 
bag.

When not in use, keep jaws slightly open and lock 
screw slightly loose to prevent over tightening due to 
thermal expansion which may affect accuracy.

Store in supplied case in a cool, dry location. Keep 
away from direct sunlight or wet locations and protect 
from use by unauthorized personnel.

EXAMPLE 1

Measured value = Main Scale R Vernier Scale Reading

7 7

0 . 0 0

7 7 . 0 0

Reading

7 7

0 . 3 0

7 7 . 3 0

Reading

7 7

0 . 3 5

7 7 . 3 5

Reading

Measured Value:  77.00mm

EXAMPLE 2

Measured Value:  77.30mm

EXAMPLE 3

Measured Value:  77.35mm

POSITIONING CALIPER ON OBJECT

Scale should be read from 
directly above the calipers. 
Due to step in height of vernier 
scale relative to main scale, if 
viewing direction is not directly 
above the reading may have 
parallax error.

Flat surfaces

When measuring features 
with flat surfaces, make sure 
the measuring surface of the 
jaws are parallel to the 
surfaces to be measured.

Cylindrical surfaces

When measuring cylindrical 
features, make sure the caliper 
jaws are perpendicular to the 
cylinder axis as shown.

VIEWING THE SCALE

Proper alignment

Workpiece

Jaw

Main Scale

1

㎜)

Vernier Scale

0.05

㎜)

Main Scale

1

㎜)

Vernier Scale

0.05

㎜)

Main Scale

1

㎜)

Vernier Scale

0.05

㎜)

I442-K

2205

Model No.

Measuring Range

Resolution

Maximum 

permissible error

Weight

Reviews: