Before using for measurements, please perform 0-Point
Calibration, and 2-Point Calibration.
Safety Precautions
Preparing to Use
Please Observe
To prevent injury to yourself and others, and to prevent
damage to property, always follow the procedures below
marked with the following symbols.
■
To prevent accident or injury, please observe the
information identified with the following notice.
Read this manual and follow the instructions.
・
Use of product other than as described in the manual
may cause accident.
Do not get wet.
・
It may cause failure.
Handle with Care.
・
Do not drop or shock product. Do not place under
heavy object or subject product to strong forces.
Improper use may case inaccuracy or damage.
・
Handle probe head with care; do not use to strike
surface as it will cause failure.
Only use to measure applicable materials.
Do not disassemble or modify.
・
It may cause damage or inaccuracy.
Keep away form high voltage and strong
magnetic fields.
・
May cause damage or inaccuracy.
Do now wipe with solvent, or solvent based
products, such as insecticide, etc.
・
It may cause failure.
Remove battery when not in use for long
periods.
Keep away from direct sunlight and high
temperatures such as in a car, or near a stove or
heat source.
・
It may cause failure.
After use, wipe off any dirt or dust, and store in
dust free location.
■
Installing battery
・
Battery not included.
Requires one AA size alkaline battery.
・
Do not move probe during measurement. Only
measure single point at a time.
・
Continuous measurements will cause the probe to
heat up, so please remove from surface and allow
probe to cool in air for
about 2 seconds
between
each measurement.
・
Always remove any dirt from probe surface before
measuring,
Alkaline AA Battery
Battery Cover
Open
Close
How To Use
■
Basic Operation
①
Turn on Power
Press and Hold the ON/OFF
・
MENU button until
“
READY
”
appears on the LCD Display.
※
Auto-Off feature will turn off power after being idle for set
period. (Initial setting is 1 minute.)
②
Measure
Press Probe face against surface, when indicator sound is
heard, measurement is complete. Thickness reading is
displayed on the LCD display.
Iron and Steel (FE) : 1 beep
Non-ferrous (NFE) : 2 beeps
③
Turn off Power
Press and Hold the ON/OFF
・
MENU button until LCD display
turns off.
Long Press
Power ON/OFF
・
MENU Button
For an accurate measurement, 0-Point and 2-Point Calibration
must first be performed using a Reference Base.
Before taking measurement,
always
calibrate using uncoated
substrate of same material as substrate used in the
measurement.
When measuring uneven shapes and pipes, calibrate using
uncoated substrate of same material and shape as the surface
to be tested.
■
Calibration Note
Rotate Battery Cover to open, Insert AA size alkaline battery in
direction shown. Please check orientation before replacing
cover.
LCD Display
Press face against surface
Probe
・
Calibration Set Value must match the thickness of
the Calibration-foil. If they do not match, change the
setting using the
“■
Changing The Preset
Calibration Value
”
procedure below.
・
Calibrate using calibration film of slightly larger
thickness than the coating you will measure. If the
calibration film thickness is very different than the
measurement film, the measurement will not be
accurate.
→
■
Calibration Note
WARNING
■
The following icons are used to indicate important
information which must be observed.
Denotes a
“
prohibition
”
:
You MUST NOT do it.
Denotes a
“
requirement
”
:
You MUST do it.
Improper use may result in personal
injury or damage to property.
CAUTION