Short press

・・・

Hold display. Press again to release.

Long press

・・・

Measu/- direction. Default is “+”

Example: For a “+” reading of 15.00°, “-” setting will display

 as follows:

For Measurement Range = 360° 

・・・・・・

 

345.00°

For Measurement Range = 180°

・・・・・・・

 

165.00°

For Measurement Range =   90°

・・・・・・・

   

75.00°

 LCD display flips 180°

Short press

・・・

360°

180°

90°

With power ON, a long press

・・・・・・

Power OFF

With power OFF, a short press

・・・・

Power ON

With power ON, a short press

・・・・・

Comparative meas. on/off

Long press

・・・

Measurement units : 

0°00′

」←→「

0.00°

360

°

MODE

ON

/

REF

HOLD

0

°

00

OFF

+/−

°/′

DIGITAL UNIVERSAL PROTRACTOR

Model No.

DUP

360AN

Thank you for purchasing the Digital Universal Protractor.

Please read this manual thoroughly before use for proper operation.

INST. MANUAL

Acute Angle Attachment

Master Square

Blade Lock Lever

Fine Adj. Knob

Fine Adj. Knob

Control Panel

Catch

300mm

 Blade

Control Panel

 

Lock Screw

LCD

 Display

Reference Arm

Precision angle measurement for machinery, jigs,

molds,  and  assembly.  Use  as  precision  angle

reference, and for angle measurement.
Easy to read digital display.
Select from three output modes: 360°, 180°, 90°
Display orientation can be flipped 180°
Angle memory saved when replacing battery.
0-Reference can be set at any position.
Acute Angle Attachment included.
+/- Angle switching feature.

Weight: 

350g

Power: 

CR3032 Lithium Battery (1x)

Accessories: 

150mm Blade

300mm Blade

Acute Angle Attachment

Master Square

CR3032 Lithium Battery (for test)

FEATURES 

 APPLICATIONS

SPECIFICATIONS 

M

PART IDENTIFICATION

1. Open battery cover (Pull out silicone rubber cover to 

remove.)

2. Insert battery with “+” side up.
3. Push battery cover back into it's original position.

Only use CR2032

battery.

CAUTION

INSERTING / REPLACING BATTERY

Cover

Pull Out

NOTICES

[ON/REF] Button (Power ON/OFF, Comparative meas. on/off)

1

[MODE] Button (Switches measurement range and units)

2

[HOLD] Button (Display hold on/off, Measu/- direction)

3

When  turned  on,  display 
w i l l   i n d i c a t e   “ R E F ”  
and 0°00' (0.00°)

Switches  measurement  range.  If  range  is 
exceeded, measurement starts back at “0”

CONTROL PANEL

Display Orientation Button

4

Blade Lock 

Lever

Pawl

Setting the Reference Point (Use supplied Master Square)

1. Press [ON/REF] Button to turn on power.

2. While holding down the Display Orientation Button

, simultaneously apply a long press to the

[MODE] Button.

3. Instrument will switch to angle setting mode and 

display a flashing                     on LCD.

4. To set the reference point, place the Master 

Square in position 

 or 

 (depending upon how it 

will be used) against the Reference Arm and Blade 

as shown. (Fig. 2)

5. Press the Display Orientation Button         to

establish this position as the 90° reference point.

Measurement

Mounting the Blade

1. Press [ON/REF] Button to turn on power.
2. Press the [MODE] Button to chose measurement range.
3. Position the workpiece between the Reference bar 

and Blade. Read the measurement from LCD. (Fig. 3)

Set  the  reference  point  using  the 

procedure above based on intended use.

Ex.) 

Once reference point is set using position 

, to switch 

faces and take measurements with the opposite face, the 

reference point must be reestablished using position 

.

If the Reference Bar does not rotate, loosen the

Control Panel Lock Screw.

The Fine Adjust Knob can be used to rotate the

Reference Bar with more precise control.

Acute Angle Measurements

1. Mount the Acute Angle Attachment onto the groove 

on the Reference Bar.

2. Rotate the Catch 90° to the Reference Bar.
3. Align the Acute Angle Attachment to the Blade and 

secure by tightening the Mounting Screw.

4. Position the workpiece between the Acute Angle

Attachment and Blade. Read the measurement

from LCD. (Fig. 5) 

Fig.1

Fig. 2

Reference Arm

Workpiece

Master 

Square

Blade

Fine Adj. 

Knob

NOTICE

Fig. 3

Fig. 4

Fig. 5

Reference 

Arm

Mounting 

Screw

Acute Angle 

Attachment

Catch

Workpiece

Blade

OPERATION

1. Select 150mm or 300mm blade as required.
2. Loosen the Blade Lock Lever. Insert the Blade 

     with the pawl securely in the groove. (Fig. 1)
3. Secure blade using the Blade Lock Lever.

Blade

Blade Lock 

Lever

Insert

SERVICE

TROUBLESHOOTING

Q. Nothing is displayed, or the numbers are flashing.

A. Is the battery running low?

Q. With power on, the number on the LCD does not change as blade is moved.

 A. Please reset by removing battery for about 30sec., and then replacing.

Q.  Nothing happens when buttons are pressed.

A. Is the battery inserted properly?

If not working properly, or if you have any questions, please contact

distributor or place of purchase.

Please  note,  manufacturer  is  unable  to  respond  to  inquires  or  provide

service directly. Please contact distributor or place of purchase.

loosen

Tighten

Control Panel 

Lock Screw

Align

Niigata seiki Co., Ltd.

5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522   Fax. : +81-256-33-5518

MAIL   [email protected]

URL    http://www.niigataseiki.co.jp

150mm

 Blade




Fine Adj. 

Knob

Battery

(+

side

Mounting Screw

Battery Cover

Display Orient. Button

[HOLD ]Button

[MODE ]Button

[ON

REF ]Button

Before use, please wipe off corrosion protectant
using a soft cloth.
This product is a precision instrument. Use care not 
to drop or subject to shock or strong force.
Do not disassemble or modify.
Do not scratch surface of Blade or Reference Arm. 
Do  not  engrave  or  use  electric  pen,  such  as  to 
engrave with ID numbers. 
Do  not  use  or  store  in  places  subject  to  direct 
sunlight,  extreme  temperate  fluctuations,  high
humidity,  or  high  levels  of  dust.  Also,  keep  away 
from water and oil. Keep out of reach of children. 
This product is precision measuring instrument. Use 
only as directed. Improper use may cause accident 
or injury.

Measuring Range: 

0-360°

Resolution:  

1' / 0.01°Maximum 

Inst. Error:   

±5' / 0.08°

Operating Temp. Range:  0 

~

 40°C