Part One – Your Nighthawk CO and Gas Alarm

Wall Mounted Alarm

First, refer to “Where to Install Your CO
and Gas alarm” on page 1-3 for general
guidelines as to where to locate your CO
and Gas alarm.

Installation tips for power cord models:

The power cord option provides more
flexibility in mounting locations and
allows the alarm to be easily installed at
eye level. 

Note:

If you mount the alarm high on a

wall, make sure it is 

at least 6" from the

ceiling

. Any higher than this, it will be in

“dead air space” and carbon monoxide or
natural Gas may not reach the sensors.

Note:

Do not cover the alarm with a curtain. 

For a wall-mount, you will need to pull out the removable
adapter and power cord. This simple process as outlined below.

To install:

1. Follow steps 1 - 4 in the previous column under “To Rotate
Adapter.”
2. With adapter out, pull out power cord and unwrap it.
3. With cord extended, press last few inches into cord recess.
Gently pull cord at bottom of cord recess until cord becomes
taught and lays flat in cord recess.
4. Carefully replace back door by making sure
“latches” on all four corners of door are lined up,
then firmly press into place.
5. Insert the screws provided until head is approx.
1/8” from wall (If mounting in plaster board or dry-
wall, drill 3/16 hole and use plastic anchor provid-
ed). Use mounting guide template in back of user’s
guide to locate holes.
6. Hook the Nighthawk CO and Gas alarm unit over the screw
onto keyhole in back of unit.
7. Plug cord into electrical outlet.

Table Top Alarm

You can also use your Nighthawk CO and Gas alarm as a table top
unit. Simply follow the above steps for removing adapter, then
instead of mounting to a wall, simply pull out slide support and
stand on table, bedside stand, chest of drawers, etc. (refer to diagram
on page 1-1).

Back of unit when used

as a wall mount for

natural gas and CO

detection

WALL

1/8"

1-5

Normal Operating Characteristics

When you first power up the unit,

the alarm will sound briefly

to let you know the unit is receiving power and that the alarm circuit
is functioning.

You should see three eights 

on the digital display, indicating

the alarm is in the start-up mode. The three eights will remain for
approximately 20 seconds. You should see a
blinking red dot to the lower right of the digi-
tal display. The blinking dot shows that the
alarm is operating.

Within 20 seconds, your CO alarm will start
monitoring for CO.  Within 2 minutes your
alarm will start monitoring for Gas.  

Note:

The number will probably

be zero (0).  This is a normal condition for most households and
shows that no measurable amount of CO or Gas is being detected.

The alarm has begun monitoring the air for carbon monoxide and Gas
and will continue to do so as long as it receives power.   

When the alarm is unplugged or loses power and you have
a good 9V battery installed,

the alarm will automatically switch

to its battery backup mode and you will notice the following:

• After 4 minutes the digital display will show a blinking dot 

only – this helps conserve the battery’s power.

• The digital display will show a number for CO or show 

“GAS” only if it senses carbon monoxide or Gas while in 
backup mode.

• If CO is detected while on battery backup, alarm pattern

is 4 quick beeps – followed by 5 seconds of silence –
followed by 4 quick beeps. After 4 minutes, this alarm pattern
occurs only every 60 seconds. 

• If Gas is detected while on battery backup, the unit will display

Gas and alarm continuously. The alarm pattern for Gas is a 1/2
second alarm on, 1/2 second of silence -repeating. For the first
four minutes after the unit goes into battery backup operation,
the explosive gas sensor will operate as if on AC power.
However, after four minutes, to extened battery life, the unit will   
go into battery conserve mode and will only sample 

for explosive gas once every eight minutes. Explosive gas could   

be present during this 8-minute period without the unit going 
into alarm. If the alarm is on battery backup for an extended 
period of time, replace the battery to ensure maximum protect-
tion is provided. The battery will last only a couple hours in a 
Gas alarm condition. 

Note: When AC power is restored, the alarm will automatically switch
back to normal operating mode.

When the alarm is unplugged or loses power and you have
a low battery installed,

you will notice the following:

• A fading alarm will sound alerting you the unit has 

switched to its backup mode, but the 9V battery is low.

Blinking Dot

CO/Gas Alarm Manual Rev. C  3/21/01  11:37 AM  Page 10

Summary of Contents for KN-COEG-3

Page 1: ... located on back of alarm Date of Manufacture located on the back of the alarm Date of Purchase Where Purchased Includes 9V Battery For questions concerning your Carbon Monoxide and Explosive Gas Alarm please call our Consumer Hotline at 1 800 880 6788 AC Powered with Battery Backup Carbon Monoxide and Explosive Gas Alarm By KIDDE Safety User s Guide See pages 4 1 and 4 2 for What to do When the A...

Page 2: ...a Gas emergency Who you should call if you suspect you have CO or Gas in your home 4 2 Sometimes it is difficult to find the source of CO 4 2 Part Five Technical Information Product Specifications 5 1 How the unit determines when to alarm 5 1 Part Six Frequently Asked Questions 6 1 2 Plus Display readings and what they mean 6 3 4 Limited Warranty Warranty Registration Back Page Warranty Service Ba...

Page 3: ...gh a main utility line con nected to your home If you do not live in a rural area you are like ly to be a user of natural Gas It is the dominant energy used for home heating with about 55 percent of American homes using Gas Natural Gas is a fossil fuel comprised almost entirely of Methane Methane is much lighter than air and will rise rapidly in air If you are a user of natural Gas we recommend yo...

Page 4: ...g for gas During this period a number will appear on the digital display The number on the digital display should be zero 0 If not see page 1 5 for complete information on normal operating characteristics Step 6 Wait 2 to 3 minutes after power up and make sure the red dot in the digital display is blinking Then test the unit s operation by pressing and releasing the Test Reset button Within 15 sec...

Page 5: ...plication These are just a few reasons over 4 5 million families have chosen Nighthawk over every other brand for this kind of life saving protection Nighthawk CO and Gas Alarm KN COEG 3 front view Nighthawk CO and Gas Alarm rear view Carbon Monoxide Alarm Explosive Gas Alarm TEST RESET PEAK LEVEL Sounder Alarm Digital Display Test Reset Button Blinking Red Dot Peak Level Button Rear view with bac...

Page 6: ...s is detected during battery backup conditions This will significantly shorten the bat tery life What Carbon Monoxide and Explosive Gas Alarms Can and Cannot Do This unit is designed to sense unacceptable levels of CO or Gas from malfunctioning furnaces appliances Gas engines or other sources This unit will provide early warning of the presence of carbon monoxide usually before a healthy adult wou...

Page 7: ...as a door or window CAUTION This alarm will only indicate the presence of carbon monoxide or Gas at the sensor Carbon monoxide or Gas may be present in other areas IMPORTANT Improper location can affect the sensitive elec tronic components in this alarm Please see the next section describing where NOT to install this alarm 1 3 Where Not to Install Your CO and Gas Alarm To avoid causing damage to t...

Page 8: ...en fireplace etc Temperature inversions which can trap exhaust Gasses near the ground Car idling in an open or closed attached garage or near a home How to Install Your Alarm Your Nighthawk CO and Gas alarm with its removable adapter allows you to install the alarm as a wall mounted unit for nat ural Gas detection and CO a direct plug unit for propane and CO or as a table top unit To install the b...

Page 9: ...e The three eights will remain for approximately 20 seconds You should see a blinking red dot to the lower right of the digi tal display The blinking dot shows that the alarm is operating Within 20 seconds your CO alarm will start monitoring for CO Within 2 minutes your alarm will start monitoring for Gas Note The number will probably be zero 0 This is a normal condition for most households and sh...

Page 10: ...incense stick by pressing the smoldering tip into the ashtray Part One Your Nighthawk CO and Gas Alarm Constant exposures to high or low humidity may reduce battery life We recommend you replace your 9V battery at least every six months How to Test Your Alarm There are two aspects of the alarm s operation that can be test ed the electronics and the sensors response Instructions on test ing each ar...

Page 11: ...l sound continuously and The digital display will be blank and The alarm cannot be shut off by pushing Test Reset button Unplug the alarm immediately and return for warranty exchange see Warranty on back page Low Battery Warning If the 9V battery is missing or if the battery s power is low an Lb message will display which blink s alternately with the current CO reading or GAS every second If this ...

Page 12: ...sing the peak level memory button Concentrations of CO between 0 and 30 PPM can often occur in normal everyday conditions Concentrations of CO below 30 PPM may be an indi cation of a transient condition that may appear today and never reappear Just a few examples of conditions and or sources that may cause low level readings are heavy automobile traffic a running vehicle in an attached garage an a...

Page 13: ...is taken for the flu headache dizziness weakness nausea vomiting sleepiness and confusion Breathing very high concentrations of carbon monoxide can be lethal in minutes Breathing low concentrations over time is dangerous too Long term exposure to low levels could cause permanent heart and brain damage Could Your Family be at Risk for CO Poisoning Carbon monoxide is the number one cause of poisonin...

Page 14: ...e What You Should Not Do Never burn charcoal inside a home garage cabin RV or camper Never install service or convert fuel burning appliances from one type to another without proper knowledge skills and tools Never use a Gas range oven or clothes dryer for heating Never operate unvented Gas burning appliances such as kerosene or natural Gas space heaters in a closed room Never operate Gasoline pow...

Page 15: ... carbon monoxide should immediately contact her physician Is there anyone in the household who is elderly or who has anemia heart disease or respiratory problems emphysema or chronic bron chitis These individuals are at higher risk for CO poisoning and for health problems from exposure to low levels of carbon monoxide If anyone in the household is at high risk for CO poisoning we urge you to take ...

Page 16: ...remises have been aired out and your CO and Gas alarm remains in its normal condition 4 After following steps 1 3 if your alarm reactivates within a 24 hour period repeat steps 1 3 and call a quali fied technician to investigate for sources of CO from fuel burning equipment and appliances and inspect for proper operation of this equipment If problems are identified during this inspection have the ...

Page 17: ...ollowed by a 1 2 second of silence then repeating Know how to respond to a CO or Gas emergency If the unit alarms for Gas 1 Evacuate the premises 2 Do not activate any electrical switch or telephone 3 Contact your fire department Treatment for CO Poisoning Any person who is suspected to have carbon monoxide poisoning should leave the potentially dangerous environment get fresh air immediately and ...

Page 18: ...nder 30 ppm Accuracy of the Digital Display Each Nighthawk CO and Gas alarm is calibrated at a CO concentration of 150 ppm in air at 80 F 10 F and 40 3 relative humid ity Depending on the ambient condition temperature humidity and the condition of the sensor the alarm readings may vary Under the same ambient conditions the device will alarm for Gas before 25 of the LEL is reached The digital readi...

Page 19: ...O or Gas exposure Please note however that the alarm will sample for the presence of gas once every eight minutes while on battery backup Gas could be present during this eight minute period without alarming Please see page 1 5 Q How do I get the alarm to show something besides 0 OR How can I determine if the sensors are operating correctly A Please refer to Testing Sensor Response on page 1 6 for...

Page 20: ...ways occupied and can have temperature extremes when no one is there no heat or no air conditioning Will that hurt the alarm Should I leave it plugged in all the time A We recommend that your alarm not be installed in areas where temperatures fall below 40 F 4 4 C or rise above 100 F 37 8 C Your alarm was designed to be constantly plugged in for maxi mum performance Q I plugged in the alarm at my ...

Page 21: ...arize yourself and other family members to the difference between a CO reading a Gas reading and a reading signifying a problem with the alarm itself Display Shows Alarm Sound Unit Status Recommended Action Brief 888 One short chirp Self checking when AC powered None Unit should return Test button was pressed or unit to zero within a minute was first powered Lb flashes One short chirp Start up or ...

Page 22: ...as unit will show reading only if it possible to conserve battery senses CO or gas Steady Err Chirp every Unit malfunctioning when Call KIDDE Safety customer and flashing dot 30 seconds battery powered service at 1 800 880 6788 Flashing dot Chirp every Very low battery Replace battery 30 seconds unit will not respond to CO Refer to Step 3 on page ii or gas No display Constant Alarm Near dead batte...

Page 23: ...Notes CO Gas Alarm Manual Rev C 3 21 01 11 37 AM Page 24 ...

Page 24: ... Nighthawk CO and Gas alarm to the wall you may use this guide for exact placement of the two wall mount screws provided For more information about mount ing to the wall please refer to page 1 4 2 58 CO Gas Alarm Manual Rev C 3 21 01 11 37 AM Page 25 ...

Page 25: ...ring the above warranty period your prod uct will be replaced with a comparable product if the defective prod uct is returned postage prepaid to KIDDE Safety Customer Service Department 1 800 880 6788 together with proof of purchase date Please include a note describing the problem when you return the unit The replacement product will be in warranty for the remainder of the original warranty perio...

Reviews: