4.2.2 OPERATION
ALWAYS ALLOW THE ENGINE TO WARM UP BEFORE OPERATING.
ALL MODELS
1)
Ensure all red emergency stops are out.
2) Turn
Base/Platform
selector at ground control station to
Ground
(Clockwise).
3) For
Battery
powered operation, go to step 7).
4) For
Diesel
powered operation, go to step 5).
DIESEL ENGINE
5)
COLD ENGINE
: - turn the
Diesel Glow/Start
selector to the
Glow
position (anti-clockwise). This
engages the glow plug pre-heat system. Hold for 10 seconds then turn the key to the
Start
position (fully clockwise) and the engine will fire.
6)
WARM ENGINE
: - turn the
Diesel Glow/Start
selector to the
Start
position (clockwise) and the
engine will fire.
Note
: Unless the diesel engine is running, the HR21 Hybrid will automatically default to the electrical
power source (battery).
ALL MODELS
7)
Push and hold green power button on the base control box.
8) Select a function and operate the appropriate hydraulic lever in full accordance with
manufacturers operating and safety manual.
Note
: Move lever until resistance is felt, then push/pull harder to activate function.
9)
To return control to the platform turn the
Base/Platform
selector to the
Platform
position (anti-
clockwise).
10) When not in use return machine to stowed position, turn the
Base/Platform
selector to centre
Off
position, remove key and chock wheels.
EMERGENCY PROCEDURES
1)
Push in red emergency stop to shut down all functions.
2)
In the event that the controls fail or the operator becomes incapacitated the booms can be
operated by using the hand pump which is located under the canopy next to the base controls.
To operate:
a) Move and hold lever to be operated.
b) Use hand pump lever to move machine.
c) Release control lever to halt machine movement.