35
English 07/16
Service Manual
HR15/17N HYBRID DC
4.2
Platform/Cage
4.2.1
Footswitch - Contact Switch replace
The footswitch is used to provide power to the Niftylift controls.
Remove
1) Isolate the power supply (See section 1.5.4).
2) Remove bolts (1) and (2) and remove the
footswitch cover and rubber gasket.
Note; the longer length of bolt (1).
3) Record wiring locations.
4) Disconnect wiring from switch terminals (3).
5) Remove 2 screws (4) from contact switch and
remove.
Install
6) Replace contact switch and tighten 2 screws.
7) Connect wiring to contact switch terminals as
observed in step 3.
8) Reinstall footswitch cover and rubber gasket
making sure bolts are in the same position as
step 2.
9) Tighten bolt (1) to 3.0Nm (2.2 ft lbs) and bolt
(2) to 2.5Nm (1.8 ft lbs).
10) Connect the power supply (See section 1.5.4).
1
2
3
4