Remarks 

 

• 

The smallest picture you get, moving the two lenses the longest way away from each other.   
To have the biggest picture, move the two lenses nearby each other in the middle of the lens tube  

• 

If you want to defocus the light, you can use the zoom lenses. Move the one lens out of the sharpness or 
moving both lenses together.  

• 

Be aware, that it is only allowed to use this method for a maximum moving the /- 30mm (outside the 
sharpness). There is the risk to have the focal point in the filter frame and destroy the filter, if you move the 
lenses in the front of the front lenses tube.  
Please use high temperature Filter Frames (like ROSCO-Supergel).  

   

Operation with Color Scrollers  

Color Scroller can be used with a special adapter or mounted directly to the luminaire instead of the Filter Frame 
Holder (9).  Be aware, using accessory in the Filter Frame Holder shift the balance point of the luminaire.   

 

Programming and operation oft he spotlight on site 

 

DMX in 

DMX out    Mini USB (for updates) 

   

 

 

 

 

 

 

 

 

 

 

     

Display 

 

 

 

 

 

 

 

 

 

 

    (DMX receive) 

 

 

 

 

 

 

 

 

 

 

    DMX startadress 

 

 

 

 

 

 

 

 

 

 

    Temperature 

 

 

 

 

 

 

 

 

 

 

    Software version 

 

 

Installation   

 

 

 

Intensity

 

DMX connection 

1.

 

The DMX In- and Output is located on the backside from the lamphouse. If no additional DMX fixture is used, the 
DMX outlet must be terminated with a 120 Ohm resistor, to avoid disturbances in the DMX network.  

 

Summary of Contents for LPZ 211 D

Page 1: ...NIETHAMMER LPZ 211 D and LPZ 215 D Niethammer LPZ 211 D and HPZ 215 D Seite 1 Instruction Manual LPZ 211 D LPZ 215 D E 211 215 201910...

Page 2: ...cy might be reduced e g in case of deep cracks or scratches The luminaire must be maintenained if some unexpected failrs are lamp must be changed if damaged or distorted by heat If internal access is...

Page 3: ...eeded clamp not included The Yoke 12 has five fixing holes 4x11mm 1x13mm diameter 1 Lamp Housing 2 Rear section Screw s to open the lamphouse 3 Accessory slot 4 Beam Shaper 5 Iris 6 Friction point 180...

Page 4: ...he fixture is equipped with temperature controlled low noise axial fans 7 The lamp housing see drawing point 1 is provided with a hinge and can easily be opened by loosening the screw s see drawing po...

Page 5: ...troy the filter if you move the lenses in the front of the front lenses tube Please use high temperature Filter Frames like ROSCO Supergel Operation with Color Scrollers Color Scroller can be used wit...

Page 6: ...re displayed either by a white cross in the red circle function deselected or by a white check mark in the green circle function active The settings are accepted with Exit in the corresponding menu If...

Page 7: ...e lamp house this can be cleaned with a vacuum cleaner with a brush attachment of dust 3 DO NOT clean the fans with a vacuum cleaner as this can induce a voltage and damage the electronics a soft brus...

Page 8: ...NIETHAMMER LPZ 211 D and LPZ 215 D Niethammer LPZ 211 D and HPZ 215 D Seite 8 Optical System LPZ 211 D LPZ 215 D...

Page 9: ...NIETHAMMER LPZ 211 D and LPZ 215 D Niethammer LPZ 211 D and HPZ 215 D Seite 9 HPZ 215D HPZ 211D...

Page 10: ...744 Neigungsfeststellgriff M10 N215 100L Cover lamp house complete N70 194 Handle lamphouse N70 326 Knurled knob lamphouse M6 Nxx xxx Knurled knob lamphouse side Mx Spareparts for LPZ 215 D Standardve...

Page 11: ...NIETHAMMER LPZ 211 D and LPZ 215 D Niethammer LPZ 211 D and HPZ 215 D Seite 11...

Page 12: ...AC 47 63Hz Input 96V 48V DC Powerconsumption max 550W Powerconsumption max 550W Photobiological datas ENILED with 3 000K LED Risk group 1 ENILED with 5 700K LED Risk group 2 Niethammer Lichttechnik G...

Reviews: