background image

NIETHAMMER 

LPZ 211 D  and  LPZ 215 D 

 

 

Niethammer LPZ 211 D and HPZ 215 D 

Seite 2 

 

Advice before Use  

• 

Read this instruction carefully.                       

• 

As soon as the equipment is delivered, open the packing and inspect the equipment carefully. If you notice 
any damage, contact the transport company immediately and register your complaint in due form listing the 
defects.                               

• 

We can assure you, that this equipment left our factory in perfect condition.  

• 

Check it the received equipment is consistent with the delivery notice and if the delivery notice is consistent 
with your order. If it is not, immediately contact your supplier.       

• 

Electrical connection from the spotlight :   1. First Spotlight <-> PSU (Harting (square plug) 

2. Second PSU <-> power supply (Powercon True1® (round plug))  

 

General Remarks  

This luminaire is lighting equipment designed for professional indoor use in theaters and televison- or film studios. 
Designed and build in accordance with EN 60950 and EN 60598-17 regulations, it must imperatively be connected 
to earth by means of its earth wire.   

To prevent any electrical shock, this equipment should not be opened when it is powered.                                         

Nevertheless:  

• 

Any parts or lenses need to be replaced if they are visibly damaged and their efficiency might be reduced, e.g. 
in case of deep cracks or scratches.                             

• 

The luminaire must be maintenained if some unexpected failrs are lamp must be changed if damaged or 
distorted by heat.                                                    

If internal access is needed for control, service or repair purposes, always refer to qualified personnel. Always be 

sure to unplug the power supply cable before opening the fixture.  

 

ATTENTION: LETHAL VOLTAGE PRESENT INSIDE !        

 

It is the user responsibility to use the luminaire for intended purpose and to check the equipment that might be 
connected to it.                             

The luminaire can under no circumstances be modified. Niethammer Lichttechnik GmbH will not assume any 
responsibility in case of damage resulting from modifications made to the luminaire.                   

This  luminaire  is  a  piece  of  professional  equipment  designed for  easy and simple  use.  Always  refer  to  qualified 
personnel  for  any  using,  installation  or  repair  work.  Avoid  installing  the  luminaire  near  inflammable  matters. 
Minimum distance between luminaire and inflammable matters is 3,2m.          
                           

Important Remark:  

Power supply cables and other connections are essential for your equipment and contribute greatly to a safe and 
trouble free operation.  

• 

Always pull the plug from the PSU cable when disconnecting a cable, never pull the cable.                   

• 

Never use cables and connectors in bad conditions, check them before installation and periodically thereafter                                                    

• 

Never tie power supply and data cables together.                  

Summary of Contents for LPZ 211 D

Page 1: ...NIETHAMMER LPZ 211 D and LPZ 215 D Niethammer LPZ 211 D and HPZ 215 D Seite 1 Instruction Manual LPZ 211 D LPZ 215 D E 211 215 201910...

Page 2: ...cy might be reduced e g in case of deep cracks or scratches The luminaire must be maintenained if some unexpected failrs are lamp must be changed if damaged or distorted by heat If internal access is...

Page 3: ...eeded clamp not included The Yoke 12 has five fixing holes 4x11mm 1x13mm diameter 1 Lamp Housing 2 Rear section Screw s to open the lamphouse 3 Accessory slot 4 Beam Shaper 5 Iris 6 Friction point 180...

Page 4: ...he fixture is equipped with temperature controlled low noise axial fans 7 The lamp housing see drawing point 1 is provided with a hinge and can easily be opened by loosening the screw s see drawing po...

Page 5: ...troy the filter if you move the lenses in the front of the front lenses tube Please use high temperature Filter Frames like ROSCO Supergel Operation with Color Scrollers Color Scroller can be used wit...

Page 6: ...re displayed either by a white cross in the red circle function deselected or by a white check mark in the green circle function active The settings are accepted with Exit in the corresponding menu If...

Page 7: ...e lamp house this can be cleaned with a vacuum cleaner with a brush attachment of dust 3 DO NOT clean the fans with a vacuum cleaner as this can induce a voltage and damage the electronics a soft brus...

Page 8: ...NIETHAMMER LPZ 211 D and LPZ 215 D Niethammer LPZ 211 D and HPZ 215 D Seite 8 Optical System LPZ 211 D LPZ 215 D...

Page 9: ...NIETHAMMER LPZ 211 D and LPZ 215 D Niethammer LPZ 211 D and HPZ 215 D Seite 9 HPZ 215D HPZ 211D...

Page 10: ...744 Neigungsfeststellgriff M10 N215 100L Cover lamp house complete N70 194 Handle lamphouse N70 326 Knurled knob lamphouse M6 Nxx xxx Knurled knob lamphouse side Mx Spareparts for LPZ 215 D Standardve...

Page 11: ...NIETHAMMER LPZ 211 D and LPZ 215 D Niethammer LPZ 211 D and HPZ 215 D Seite 11...

Page 12: ...AC 47 63Hz Input 96V 48V DC Powerconsumption max 550W Powerconsumption max 550W Photobiological datas ENILED with 3 000K LED Risk group 1 ENILED with 5 700K LED Risk group 2 Niethammer Lichttechnik G...