Nielsen DA118 Equipment Manual Download Page 8

EQUIPMENT MANUAL:  
MODELS DA118 and DA120 PPM 360 Meter 
Document #:  1050-xxxx 
Revision:  B 

 

CONFIDENTIAL AND PROPRIETARY INFORMATION 

 

Copyright © 2015 The Nielsen Company. All rights reserved. 

 
 

 

 

The Models DA118 and DA120 PPM 360 Meter is a device that is worn or carried on a person, 
usually by means of a belt clip.  The PPM 360 Meter collects audio that is watermarked (also known 
as “encoding”) with data information using Nielsen Audio’s patented Critical Band Encoding 
Technology, and using cellular technology, forwards this information back to Nielsen Audio data 
collection servers. The DA118 and DA120 also determines if the person wearing the PPM 360 Meter, 
known as a “panelist”, is in his/her home or out of the home using an In-Home Beacon. The Models 
DA118 and DA120 use a Headphone adapter accessory when the panelist is wearing headphones to 
collect this data from MP3 or other audio devices that use headphones. 

 

Charging of the Nielsen Audio Models DA118 and DA120 PPM 360 Meter is performed by a Class 2 
power unit with USB type connector, or alternatively by use of a cradle system which interconnects 
between this same power unit and the meter.  The cradle system uses the same Class 2 power unit 
with USB type connector; however, the cradle is a nest where the power from the class 2 power unit 
USB type connector is transferred to a set of spring pins which contact with two charge contacts on 
the side of the Models DA118 and DA120 meter when the meter is placed in the cradle nest, thereby 
charging the meter.  The cradle charging system is also an accessory of the Models DA118 and 
DA120. 

 

 

 

Figure 1 below illustrates the interactions of the Models DA118 and DA120 device with the outside 
world as well as with other components of the system overall. 

Summary of Contents for DA118

Page 1: ...n customers or authorized recipients only any reference or its use in whole or part for any other purpose without express written permission from Nielsen is expressly prohibited Nielsen Audio PPM is c...

Page 2: ...mpany All rights reserved 2 Table of Contents Nielsen Audio Trademarks Included 3 Contacts 5 Disclaimer and Limitation of Liability 6 Product Overview 7 DA118 and DA120 Main Functions 10 DA114 Main Fu...

Page 3: ...demarks are further included in this document by this list Mark Type ARB TV TM Arbitron iBoard TM Arbitron Internet Board TM Arbitron Logo ArbitrendsSM SM Arbitron Arbitron Data ExpressSM ADE SM Arbit...

Page 4: ...PM WeekliesSM SM PrintPlus PRINTSCANSM SM PROSPECTORSM SM QUALITAPSM SM QualiZip RADAR RADAR Logo Radio County Coverage TM Report DesignerSM SM Represent TM Represent Be Heard Be Rewarded TM Represent...

Page 5: ...ct Nielsen as indicated below For Radio Email EncodingOperations Nielsen com Call 410 312 8123 For Other Media Email USEncoding Nielsen com Call 410 312 8199 For any URGENT Encoding Equipment Issues p...

Page 6: ...NIELSEN ALSO DISCLAIMS AND MAKES NO REPRESENTATIONS WARRANTIES OR PROMISES EXPRESS OR IMPLIED TO YOU AS TO THE SUCCESS OF YOUR EFFORTS PURSUANT TO THIS EQUIPMENT MANUAL OR THE EXERCISE AND USE OF THE...

Page 7: ...o as the PPM G2 Personal People Meter Generation 2 Meter Accessory item Model DA114 Nielsen Audio PPM 360 In Home Beacon Also referred to as the In Home Transmitter Meter Accessory item Model DA116 Ni...

Page 8: ...e adapter accessory when the panelist is wearing headphones to collect this data from MP3 or other audio devices that use headphones Charging of the Nielsen Audio Models DA118 and DA120 PPM 360 Meter...

Page 9: ...and DA120 PPM 360 Meter Document 1050 xxxx Revision B CONFIDENTIAL AND PROPRIETARY INFORMATION Copyright 2015 The Nielsen Company All rights reserved 9 Figure 1 Interaction of PPM 360 Meter System PP...

Page 10: ...ress The In Home Beacon function does not support Bluetooth connectivity data transmission or other functions In addition meter Bluetooth cannot be searched 4 The purpose of the alternate equipment PP...

Page 11: ...y if the panelist wearing the PPM 360 Meter is beyond transmission range of the In Home Beacon it is determined that the panelist is not within the home The DA114 In Home Beacon is comprised of a simp...

Page 12: ...The SAR limit set by the FCC is 1 6 watts per kilogram W kg Tests for SAR are conducted using standard operating positions accepted by the FCC with the device transmitting at its highest certified po...

Page 13: ...y Worn Device Limited Charge Voltage 4 2V Rechargeable Battery Li Ion 4 2V 960mAh Class III device supplied by Certified Power Supply Equipment Name PPM 360 Recharger Cradle System Model DA119 Dimensi...