background image

Kestrel

®

 4200 Pocket Air Flow

®

 Tracker

5

TABLE OF CONTENTS

GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
NAVIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SPECIAL FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
MAIN SETUP MENU  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
APPLICATION EXAMPLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
MEMORY CAPABILITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DEFAULT SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
FREQUENTLY ASKED QUESTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
CUSTOMER SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Congratulations on the purchase of your Kestrel 4200 Pocket Air Flow Tracker! The Kestrel 4200 is 

our newest and most comprehensive HVAC-specific instrument. It not only measures EVERY major 

environmental condition easily, accurately and right in the palm of your hand, but now also automatically 

calculates Volume Air Flow (CFM) and Humidity Ratio (grains).
While the Kestrel 4200 is user-friendly and simple to use, reading the instruction manual is recommended in 

order to use the Kestrel 4200 to its fullest potential.
NK, manufacturer of Kestrel Pocket Weather Meters, is available to answer questions 

and provide support. Contact NK by phone: 610.447.1555, fax: 610.447.1577, email: 

[email protected], or web: www.nkhome.com.

GETTING STARTED

Pouch and Lanyards

Wrist and neck lanyards and a small pouch have been provided. To install the lanyard, 

feed the thin end of the lanyard around the metal post on the battery door (as shown 

in diagram). Feed the thick end of the lanyard through the loop on the thin end. Using 

tweezers can help.
Battery Installation

Use only AAA batteries. Install batteries as indicated on the battery door. After installing 

the batteries, the Kestrel 4200 will automatically start in the Date and Time Setting mode. (See Date and 

Time Setup below.) Custom settings and chart data will be saved during a battery change; only the date/

time and MMA values will be lost. 
Turning the Kestrel Meter ON and OFF

To turn the Kestrel Meter ON, press   the button. To turn the Kestrel Meter OFF, hold the   button for two 

seconds. Or, press the   button, then press the   button with the word OFF highlighted. (Note: your unit 

will continue to automatically store data when the power is turned off.) When first turned on, the Kestrel 

Meter will display a splash screen displaying the model number, the battery indicator, and the code version. 

This battery indicator will indicate the percentage of battery life remaining, which is helpful in preventing 

unexpected dead batteries.
Date and Time Setup

The first time that you turn on your Kestrel Meter, as well as after a battery change, you 

will need to set the date and time. The Introduction Screen will appear for 3 seconds, 

followed by the Date/Time Setup Screen. Press the   and   buttons to scroll through 

the settings. Press the   and   buttons to scroll through the setting options. After 

Shop for Kestrel products online at:

1.877.766.5412

www.

KestrelStore

.com

Summary of Contents for Kestrel 4200

Page 1: ...acker 4200 Pocket Air FlowTracker with Backlight In a hurry Be sure to read pages 5 7 to ensure that your Kestrel is setup properly www kestrelweather com 800 784 4221 Revised 07 28 10 Shop for Kestre...

Page 2: ...to enter and exit Main Setup Menu IMPELLER Zytec V bearings on a user replaceable impeller IMPELLER COVER Swivel cover protects impeller when not in use DATA UPLOAD OPTICAL COUPLER Software and seria...

Page 3: ...rd through the loop on the thin end Using tweezers can help Battery Installation Use only AAA batteries Install batteries as indicated on the battery door After installing the batteries the Kestrel 42...

Page 4: ...hat the cursor will remain at the same date and time If new data is stored while viewing chart data the entire chart will shift left with the new data point charted on the right The cursor will not sh...

Page 5: ...minute Press the button within one minute to deactivate the light manually Airflow The Kestrel Air Flow Tracker will display the volume airflow based on the instantaneous air velocity and cross secti...

Page 6: ...that point the RH value is stable and can be relied upon to be within the accuracy specifications Barometric Pressure and Altitude Adjustment The Kestrel Meter measures station pressure the actual air...

Page 7: ...ou should ignore the values on the BARO screen since the pressure changes will be due to changes in elevation far more than to changes in the weather In general changes in barometric pressure associat...

Page 8: ...Max Avg data is cleared Chart data will remain intact Press or to clear the MMA Auto Store On Off When On data is automatically stored at preset Store Rate When Off data is only stored when manually c...

Page 9: ...etup Menu User Screens The three User Screens can be reconfigured to display the most appropriate information for your application For example if you need to monitor the wind speed humidity and barome...

Page 10: ...ion for instructions Then adjust the calibrating setting on the Baro Cal screen to the known mean sea level barometric pressure If recalibration is desired the unit may also be returned to NK for serv...

Page 11: ...xamine the effect on the environment when employees enter and exit the building HVAC R System Balancing Auto Store Off Store Rate Overwrite Off Man Store On These settings will require you to press th...

Page 12: ...into your location Falling pressure indicates the arrival of a low pressure system and expected precipitation or storm conditions Steady or rising pressure indicates clear weather A correct altitude...

Page 13: ...physiology guides use wet bulb temperature rather than heat index as a measure of the safety of exercise in hot and humid conditions Wind Chill The cooling effect of combining wind and temperature Th...

Page 14: ...ic device and it will display a wind speed Or wave a magnet like a refrigerator magnet back and forth by the Kestrel Meter If the Kestrel Meter is working properly you will register a wind speed readi...

Page 15: ...ue to improper use or neglect including corrosion damage caused by severe or excessive impact crushing or me chanical harm modifications or attempted repairs by someone other than an authorized NK Kes...

Page 16: ...es Incoming and outgoing data is supplied with the certificate of calibration We also offer full factory service on every product we manufacture for as long as we make the product and as long after as...

Page 17: ...tion Manual for Kestrel 4200 version 4 29 ALL NIELSEN KELLERMAN 21 Creek Circle Boothwyn PA 19061 Phone 610 447 1555 Fax 610 447 1577 Web www kestrelweather com Email kestrel nkhome com Please registe...

Reviews: