Installation instructions for experts
p. 17/24
WARNING
NIECO infrared heaters have an installed safety temperature limiter. This
must be located at the top when the heater is mounted on the wall.
Pay attention to the installation orientation of the heater! The terminal
box with the cable must be located at the top. See Figure 6.
Fig. 6 Correct installation of the heater
7. Position the heater centrally in the cut-out. Make sure that the distance to
the wall is the same all around the heater.
8. Screw the infrared heater tight to the cabin wall using the wood screws (3 x
40 mm) provided. See Figure 7.
9. Reposition the infrared heater’s glass panel and screw tight, applying max.
0.2 Nm of torque.
WARNING
Tighten the screws to fasten the glass panel to max. 0.2 Nm. Other-
wise, the glass panel may be damaged.