background image

W A R N I N G :

Improper installation, adjustment, alteration, maintenance can cause property damage, injury, or death.

Read the installation, operating and maintenance instructions thoroughly before installing or servicing

this equipment.

F O R   YO U R   S A F E T Y:

Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other

appliance.

APPROVALS:

IMPORTANT: RETAIN THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE

Broiler area must be kept free of combustible materials, and the flow of combustion and ventilation air

must not be obstructed. Operating personnel must not perform any maintenance or repair 

functions. Contact your Nieco Authorized Dealer.

Model JF61 Gas

Owner’s Manual

BroilVection

Summary of Contents for BroilVection JF61

Page 1: ...store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance APPROVALS IMPORTANT RETAIN THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE Broiler area must...

Page 2: ...2 Nieco Corporation Model JF61G This page intentionally left blank...

Page 3: ...uirements 7 B 5 Clearance 7 B 6 Gas Connection 8 B 7 Flexible Gas Line Installation 8 B 8 Restraining Device 9 B 9 Electrical Connection 9 B 10 Pre Operation Check 9 C operation 10 C 1 Controls and In...

Page 4: ...bility of the purchaser and aRe noT covered under warranty The warranty does not extend to Damages caused in shipment or damage as a result of improper use Installation of electrical service Normal ma...

Page 5: ...as been factory trained and has a complete supply of parts for your Nieco Automatic Broiler You may contact the factory direct at 1 707 284 7100 if you have trouble locating your local Nieco Distribut...

Page 6: ...s The nieco Corporation does not endorse the use of any particular cleaning degreasing agent Use only those chemicals that are approved for use in your kitchen The broiler should be grounded according...

Page 7: ...ventilation hood of adequate size Do not obstruct the flow of combustion and ventilation air An adequate air supply must be available for safe and proper operation For installations in the Commonwealt...

Page 8: ...t contain chemicals or produce substances listed by the State of California to either cause cancer birth defects or other reproductive harm Nieco Corporation Model JF61G For safety in the kitchen area...

Page 9: ...used with all moveable castered appliances It fully complies with American Gas Association requirements References Z21 69 Z83 11 and Z21 41 with current revisions Installation is quick and positive In...

Page 10: ...it does not ignite properly 2 On off light Glows green when the broiler is on 3 Main on off switch Turns the power to the broiler on and off 4 Temperature Control P N 25918 Helps keep the broiler temp...

Page 11: ...t products 3 ADJUSTMENT BUTTONS Use to adjust product cook times element settings and product names 4 SELECTION INDICATOR LIGHT Lights up to show which button is selected 1 3 4 2 Multi speed control P...

Page 12: ...l will reset and try again for 10 seconds This occurs 3 times If the broiler does not light after the third attempt the ignition failure light will flash and the main on off switch must be cycled to r...

Page 13: ...nt of power failure gas pressure loss or any other related incident No attempt to operate this appliance should be made in the event of a power failure CaUTIon In a prominent location post instruction...

Page 14: ...sure all pieces of the broiler are in place Make sure the broiler is plugged in and the exhaust hood is turned on Turn the broiler on Step 2 Flex side Set the temperature bottom number to 1000 F 537...

Page 15: ...up and down arrows 2 to make changes then press the center square button 3 to save them 4 Changing burner settings Press the product selection button you wish to change Press the product selec tion b...

Page 16: ...n a DaIlY basIs Unless oTHeRWIse noTeD follow the steps for proper disassembly Reverse the order for reassembly CaUTIon follow the Disassembly and Reassembly steps to ensure proper operation of the br...

Page 17: ...tment Sink No Scratch Pad Scrub Pad Towel Heat Resistan t Gloves Degreaser Soft Bristle Brush Small Orifice Brush Shaft Cleaning Tool Tools Needed 1 2 This Stop sign shows a step in the procedure that...

Page 18: ...Clean Every 4 hours Scrub Pad 1 Pull the release pin 2 Lift push bar feeder base up and off 3 Wash rinse and sanitize in the 3 compartment sink DO NOT lift the feeder base by the feeder bar or the cha...

Page 19: ...feeder housing on brackets Feeder Housing Feed End Tools Instructions 3 Compartment Sink Clean Daily Scrub Pad 1 Lift and remove 2 Wash rinse and sanitize in the 3 compartment sink REASSEMBLY Hang fee...

Page 20: ...sanitize in the 3 compartment sink Grease Pan Feed End Tools Instructions Clean Daily 3 Compartment Sink Scrub Pad Heat Resistant Gloves Degreaser 1 Slide warming pan shield out 2 Take to sink area an...

Page 21: ...nk Holding Pan Bracket Feed End Tools Instructions Clean Daily 3 Compartment Sink Scrub Pad Heat Resistant Gloves Degreaser 1 Slide crumb tray out 2 Take to sink area and spray with degreaser 3 Wash w...

Page 22: ...l and wipe product holding area Product Holding Area Feed End Tools Instructions Soapy Towel Clean Daily Sanitized Towel 1 Lift up and off 2 Take to sink area and spray with degreaser 3 Wash rinse and...

Page 23: ...tions Clean Daily 3 Compartment Sink Scrub Pad Heat Resistant Gloves Degreaser 1 Tilt stripper blade away from chain lift off brackets Make sure stripper blade is cool before putting in water or it ma...

Page 24: ...n Daily 3 Compartment Sink Scrub Pad Heat Resistant Gloves Degreaser 1 Lift and slide the grease trough out of the broiler 2 Take to sink area and spray with degreaser 3 Wash with a scrub pad rinse an...

Page 25: ...before reassembly Dry with a paper towel Lower Burner Side Tools Instructions Clean Daily Heat Resistant Gloves Scrub Pad EXTREMELY HOT Be careful not to burn yourself 1 Grasp handle and lift Incendal...

Page 26: ...Top Tools Instructions Clean Daily 3 Compartment Sink Scrub Pad Heat Resistant Gloves Degreaser CAUTION Extremely Hot EXTREMELY HOT Be careful not to burn yourself 1 Lift upper heat shield up and off...

Page 27: ...clean any clogged burner holes Be sure that both air box assemblies are installed and sit flush on their brackets Upper Burner Air Boxes Top Tools Instructions Clean Daily 3 Compartment Sink Scrub Pad...

Page 28: ...an Monthly Flat Head Screwdriver 1 Remove the left side control box cover 2 Remove the ceramic boot from the back of the flame sensor 3 Loosen the wing nut holding the flame sensor in place 4 Remove t...

Page 29: ...h belts on the discharge end with the wide end of the shaft cleaning tool The tool is located on the clip on the discharge end of the broiler 2 Wipe shaft cleaning tool with a towel Chain Shafts Disch...

Page 30: ...ed in Manual gas valve if equipped is on Burners are installed properly Burners are clean and dry Flame sensor wire connection Follow manual lighting instructions Check the items above for burners not...

Page 31: ...31 Nieco Corporation Model JF61G f WIRInG DIaGRaMs 115V Wiring...

Page 32: ...32 Nieco Corporation Model JF61G f WIRInG DIaGRaMs 220V Wiring...

Page 33: ...ated here Doing so will affect the opera tion of your broiler Nieco Corporation Model JF61G G sPeCIfICaTIons AUTOMATIC BROILER Model JF91 DIMENSIONS INCH MM Length 39 36 1000 Height 34 50 876 Width 15...

Page 34: ...34 Nieco Corporation Model JF61G This page intentionally left blank...

Page 35: ...35 Nieco Corporation Model JF61G This page intentionally left blank...

Page 36: ...492 707 284 7100 Office 707 284 7430 Fax www nieco com e mail service nieco com Printed in the USA 2012 Nieco Corporation All Rights Reserved Revision History Date Notes REV 7 1 2014 Released A 12 21...