OPERATION

Preparation Before Test
Choose appropriate attachment and install it on the gauge before 
test.
(1) Pull Test: Choose pull attachment and install it on the connector 
marked [PULL].
(2) Push Test: Choose push attachment and install it on the connec-
tor marked [PUSH].
(3) Use of Extension Rod: When it isn’t possible to reach item under
test, add extension rod with attachment.

Note:  When  operating,  tested  object  and  gauge  must  be  on  the 
same straight line. If not properly aligned, correct load values are 
not possible and damage to gauge may occur.

(4) Confirm operation method by the location of the knob controller:
Changing from [PEAK] or [TRACK]: Lightly press knob inward, then 
turn it to align dot on knob (•) with either [TRACK] or [PEAK] text on 
the gauge.

Note:  After testing, place the dot (•) in the [PEAK] location. If knob
is left in the place of [TRACK] for an extended period, the life of the
inner springs will shorten.

(5) Adjustments of indicator dial:  Confirm needle aims at zero [O] 
on dial. If not, turn adjustable outer circle of dial until needle aligns 
with zero [O] on
gauge face.

Testing

(1) Please tightly hold gauge by hands or appropriate stands to per-
form test. When testing, please place tested object and gauge on 
the same straight line. If they are not aligned, test will not be accu-
rate.

(2) Change of load mode testing
(a) When knob controller is in [TRACK] mode, the needle moves in 
accordance with changes in force.
(b)  When  knob  controller  is  in  [PEAK]  mode,  the  needle  records 
Max. value of load and remains at that maximum force until pressing 
inward on the controller knob. Once knob is pushed, the needle re-
turns to zero position as long as the tested force is removed.

DIMENSIONS

Attachments

In order for the gauge to produce a stable value, please utilize in-
cluded attachments. If your company wants to utilize its own attach-
ments, please refer to size of attachment connector.

Maintenance

(1)Do  not  apply  loads  exceeding  the  max  test  range  of  gauge  to 
avoid damaging instrument..
(2)Do not put or use gauge in low or high temperature and humidity 
locations. Please store and use it in the specified environment.
(3)If there is something wrong with gauge, please contact the origi-
nal sales department you purchased from.

Model

Range Capacity

Resolution

Min. Load

MFD-02

4.5 lb (2 kg)

0.02 lb (0.02 kg)

0.45 Ib (0.2 kg)

MFD-03

11 lb (5 kg)

0.05 lb (0.05 kg)

1 Ib (0.5 kg)

MFD-04

22 lb (10 kg)

0.1 lb (0.1 kg)

2.2 Ib (1.1 kg)

MFD-05

45 lb (20 kg)

0.2 lb (0.2 kg)

4.5 Ib (2.2 kg)

MFD-06

110 lb (50 kg)

0.5 lb (0.5 kg)

11 Ib (5.5 kg)