7
GENERAL INFORMATION
Powerdrive MD2SL Installation and maintenance
5077 - 2017.12 / b
en
1 - GENERAL INFORMATION
1.1 - General
The
POwERDRIVE MD2SL
is a liquid-cooled variable speed
drive which combines a diode/thyristor rectifier and an IGBT
inverter. The high performances of
POwERDRIVE MD2SL
allow to control:
- Induction motors without speed sensor (open loop mode
select
) for applications that do not need rated torque
control above 1/10
th
of the rated speed.
- Asynchronous or synchronous permanent magnet motors
with virtual speed feedback (flux vector mode with software
sensor function
) for applications that require rated torque
control from 1/20
th
of the rated speed.
Combined with the MDX-ENCODER option. the
POwERDRIVE MD2SL
is a drive that can also be used to
control asynchronous or synchronous magnet machines for
applications that require very high dynamic performances.
torque control from zero speed or high speed accuracy
(closed loop vector mode with speed feedback
).
The performance of the
POwERDRIVE MD2SL
is compatible
with use in all 4 quadrants of the torque/speed plane with the
braking module option.
With IP54 protection (optional). installation is possible directly
in the machine environnement.
Product designation
POwERDRIVE MD2S L 180 T
*
Drive version
MD2S : 6 pulses
MD2T : 12 pulses
MD2E : 18 pulses
MD2W : 24 pulses
MD2R : AFE
Rating in kVA
3-phase power
supply
T : 400 V to 480 V
TH : 525 V to 690 V
Modular variable
speed drive with
flux vector control
Cooling:
- : Air
L : Liquid
(*) See the corresponding installation manual
Nameplate
ENTREE - INPUT
Ph V (V)
Hz (Hz)
I(A)
3 400-480 50/60
295
TYPE :
S/N :
09999999999
MADE IN FRANCE
Powerdrive MD2SL 180T
Alim auxiliaire 200VA
I(A) = maximum input current for 400 V mains supply. in
normal duty
The nameplate can be found inside the cabinet door at the top
(another copy can be found on the outside of the cabinet. at
the top on the right-hand side).
1.2 - Environmental characteristics
Characteristic
Level
Protection
IP21 (higher degree of protection
can be achieved on request)
Ambient temperature
- Storage and transport
- Operation
-25°C to +60°C (12 months max)
-10°C to +40°C. up to 50°C with
de-rating (Please contact Emerson
Industrial Automation)
Altitude
< 1000m without de-rating
> 1000m up to 2000m max :
• 1% output current de-rate per 100m
(E.g. for 1300 m. de-rate the Ico and
Imax currents by 3%)
• 0.6°C Operating temperature de-
rate per 100 m (E.g. for 1300 m. the
electrical characteristics are
maintained for an ambient
temperature of [40°- (3 x 0.6°)] =
38.2°C.)
Climatic conditions:
- Atmospheric pressure :
- Humidity :
According to IEC 60721-3-3
Class 3K3
- 700 to 1060 hPa
- <90% RH non condensing
Contamination level
In accordance with IEC 60721-3-3
• class 3B1 for biological substances
• class 3C2 for chemical gases
• class 3S2 for solid particle
Vibrations :
- Transportation in the
protective packing
- Operation
3.5mm (2 - 9Hz)
10m/s² (9 - 200Hz)
± 1 mm 3.5mm (2 - 13.2Hz)
7m/s² (13.2 - 200Hz)
Shocks (pakaged
product)
In accordance with IEC 60068-2-29 :
100m/s². 11ms
Cooling
See §
Coolant
Characteristics
Level
Temperature cycle
In accordance with IEC 60068-2-14
-10°C to +40°C. 5 cycles
Acceptable liquids
Drinking or demineralised water or a mix
of water and glycol up to a 50%-50%
ratio.
Liquid temperature
See §