![background image](http://html1.mh-extra.com/html/nidec/eg115/eg115_installation-and-operating-instructions-manual_1687859015.webp)
www.graessner.de
gahe / BA EvoGear status as of July 13, 2021
Page 15 of 22
7.4 Installation of the other Add-on Components
The drive and output elements (gears, belt wheels, cardan shafts etc.):
•
must have been balanced with G 6.3,
•
must only be fitted using suitable fitting and withdrawal devices,
•
must be axially secured even if they have been shrunk on.
When using suitable tensioning elements, the tightening torques must be taken into account.
The components must be mounted onto the shaft as far as is specified
in the article-related dimension sheet.
In the case of a belt drive, the correct belt tension must be assured and the manufacturer's instructions must be
complied with. The permissible transversal forces for the shaft must not be exceeded (see catalogue).
Drive and output elements must be covered by contact protection.
7.5 Final Work
•
Before fitting protective covers, check the correct oil level in the gearbox, if possible.
•
Check for even running free from strains, stresses and any faults.
•
Fit protective covers.
•
Carefully clear away all tools as well as any parts not fitted.
Attention
Due to
incorrect installation
, the gearbox can be damaged and become
unusable, e.g. due to falling objects, spillage, welding work or insufficient
fastening.
The operator must ensure:
•
The gearbox must be protected against any falling objects and spillage
•
Welding work must not be carried out on any part of the input
•
The gearbox must not be used as a grounding point for electric welding work
•
All mounting options assigned to the build type must be used.
•
Any screws that have become unusable during assembly or disassembly must be
replaced by new ones featuring the same design and strength class.