11
4.3 Internal oscillation emission
・
On “INT”, the Xenon lamp flashes at the displayed emission count.
・
”INT” has the following 2 mode settings.
Mode settings
FPM mode
PHA mode
Instructions
Set the emission count per minute
[FPM] (flashes per minute)
Shift the timing of flash.
The phase can be changed by a
degree or a millisecond.
( One cycle is 360°)
Display of INT
4.3.1 FPM mode setting (INT)
The emission count (frequency) can be set in FPM mode.
Turn the dial in a CW direction to increase the emission count, and in a CCW direction to decrease it.
(Turn the dial fast to change the setting value greatly, and slowly to change it slightly.)
Operation
Display
Increase / decrease
The emission count
(frequency)
Press “SIG” to
switch to the “EXT”
Mode display
The emission count (frequency)
Display
“INT”
SELECT number
CW
Decrease
Minimum value is 30
CCW
Increase
Maximum value is 35000
INT
EXT