Page 43
Symptom
Cause
Remedy
Vibrations
Defective or dry bearings.
Replace defective bearings.
Misalignment of generator
and prime mover.
Align the generator set.
Generator not properly
mounted.
Check mounting. Correct defective mounting.
Transfer of vibration from
another source.
Isolate the generator set from the source of vibration
by installing vibration dampeners between generator
set base and foundation.
Installation and Maintenance Equipment
List of equipment required for installation and maintenance. See
Table 5.
Type
Name
Notice
Test equipment
Ammeter
Clamp-on, 0 to 500 A range for measuring electric
current.
Multimeter
Digital, for measuring voltage, current, frequency,
and resistance.
Thermometer
For measuring temperature in Celsius.
Megger
To measure insulation resistance.
Resistive Bridge
To measure resistance of windings.
Special tools
Bearing puller
For changing bearing.
Exciter puller
For pulling exciter armature.
Standard tools
Cable tool
Crimping
Flashlight
As required.
Grease gun
For lubricating bearings.
Hammer
Soft-faced.
Lamp (incandescent)
Safety light.
Screwdrivers
Standard, sized as required.
Phillips, sized as required.
Wrench
Adjustable, 12-inch.
Torque 0 to 100 ft-lb.
Wrench set
Allen, 1/8 to 1/2 inch.
Socket, 1/4 to 1 inch with 3/8 and 1/2 inch drive.
Standard, open-end/box-end combination sized 1/4
to 1 inch.
Vacuum
Electric with nonmetallic nozzle.
Materials
Air
Compressed, dry.
Corrosion inhibitor
Daubert Nox-Rust VC #10 Oil or equivalent.
Covering material
Waterproof desiccant bags for protection from
moisture during long-term equipment storage.
Detergent
As required for cleaning.
Gloves
Chemical-protective and electrical protective
Heaters
Space heater, for eliminating excess moisture in
damp areas and dry out of motor or generator
windings.
Oil
STP Oil Treatment for assembly.
Plastic
Protection for long-term storage.
Rags
As required for cleaning.
Sealants
Threadlocker Loctite 242, Sealant Loctite 587 and
Curil-T, Gasket Sealant Loctite Hi-Tack.
Tags
Warning and cautions.
Water
Warm, clean water for cleaning..
Table 5 Installation and Maintenance Equipment
Summary of Contents for 4P10
Page 8: ...Page 8...