background image

Method of operation 

By performing the following operations, it is possible to observe on the 

oscilloscope how the 10MHz output of the slave is phase-locked to the master 

and the rises of 1pps are aligned with microsecond accuracy.

 

1

 

Complete  the  above  connection.  Next,  10MHz  output  and  1pps  output  are  each 

monitored with an oscilloscope. 

1.1

 

Compare 10MHz with master and  slave, and when trigger is applied to master, 

slave signal flows to either right or left (frequency is different). 

1.2

 

When 1pps is compared between the master and the slave, the rising position is 

observed to be off by more than 1 microsecond. 

2

 

How to phase lock the slave module clock to the master module clock 

2.1

 

Press the “Lock” button on the Slave module, or 

2.2

 

Press the “remote Lock” button on the Master module. 

2.2.1

 

Then  10MHz  will  phase  lock  within  a  few  seconds,  and  the  slave  signal  is 

observed to stop flowing. 

2.2.2

 

After the 10MHz phase lock is observed, the rise of 1pps is alighned within 5 

seconds with an accuracy of less than 1 microsecond. 

2.3

 

Pressing  the  “remote  Lock”  button  on  the  Master  module  again  will  result  in 

“Unlock” or “Remote Unlock”. (From here, the frequency and phase will gradually 

shift by freerunning stability) 

Summary of Contents for WIWI2GOUKI

Page 1: ... Frequency Range 922 5MHz 927 5MHz Product description This product provides synchronized signals when used in pair Modules are synchronized through 920MHz radio signal and outputs 10MHz and 1pps pulse per second signal Figure 1 overview of purpose description Module 1 Module 2 10MHz 1pps 920MHz wireless ...

Page 2: ...n method Connect the antenna and AC adapter 5V to the WiWi module no USB cable connection required Monitor 10Mhz output and 1pps output with an oscilloscope Antenna AC adaptor USB Cable 1pps Out put 10Mhz Output ...

Page 3: ...pared between the master and the slave the rising position is observed to be off by more than 1 microsecond 2 How to phase lock the slave module clock to the master module clock 2 1 Press the Lock button on the Slave module or 2 2 Press the remote Lock button on the Master module 2 2 1 Then 10MHz will phase lock within a few seconds and the slave signal is observed to stop flowing 2 2 2 After the ...

Page 4: ...3 How to reset 3 1 Slave module reset 3 1 1 Press the Reset button on the Slave module or 3 1 2 Press Remote reset on the Master module 3 2 Reset Master module 3 2 1 Press Reset on the Master module ...

Page 5: ...t installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer...

Page 6: ...CAUTION Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment ...

Reviews: