A.
SECURITY INFORMATION
Please read carefully the instruction, which includes important information about the
installation, usage and maintenance; Keep this user guide for future consultation
This product is for professional use only! Flashing lights is known to trigger epileptic seizures to people
who are photosensitive.
-
Unpack and check carefully that there is no transportation damage before using the unit
-
Do not stare directly into the light. Never look at an exposed lamp while it is lit.
-
Always unplug the device before lamp or fuse replacement.
-
Do not remove the rear cover : there are no user-serviceable part inside.
-
Do not expose the fixture to rain or moisture
-
Never operate the fixture with the front glass open, missing or damaged
-
Replace the lamp when it becomes defective or worn out (follow the instructions detailed in
section D « REPLACE THE LAMP OR FUSE »)
-
When replacing the lamp, allow the fixture to cool for at least 15 minutes before opening the
fixture or removing the lamp
-
Always ground (earth) the fixture electrically
-
Keep all combustible/flammable materials and liquids at least 0.50m away from the fixture.
-
Minimum distance to illuminated surface : 10M
-
Be sure to locate the unit in a place with adequate ventilation. Be sure that no ventilation slots are
blocked.
-
Be careful that no liquids or other objects can enter into the unit. If this ever happens, disconnect
the main power immediately.
-
The exterior of the fixture can reach temperatures up to 120°C. Allow the fixture to cool down for
at least 15 minutes before handling
-
Do not operate the fixture if the ambient air temperature exceeds 40°C.
-
When suspending the fixture above ground level, verify the structure can hold at least 10 times
the weight of all installed devices.
-
Use approved means of secondary attachement such as safety cables..
-
Avoid extending periods of continuous flashing, particularly at frequencies of 10 to 20 flashes per
second.
B.
TECHNICAL SPECIFICATIONS
-
Power : AC230V, 50/60Hz
-
Current consumption : 8A
-
Lamp : Strobe XENON PX-3000
-
Fuse : 32 amp
-
Dimensions : 472 x 152 x 255 mm
-
Weight : 6.7kg