background image

 

1. SAFETY INSTRUCTIONS 

   

 

    

WARNING  

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive 

this instruction booklet. 

Caution

 

 

All fixtures are intact from the manufacturer, please operate follow up the user manual, artificial fault are not under 
guarantee repair. 

 

Unpack and check carefully there is no transportation damage before using the unit. 

 

Do install and operate by operator. 

 

Use safety chain when fixes the unit. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.  

 

Before operating, ensure that the voltage and frequency of power supply match the power requirements of the 
unit. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Maximum ambient temperature: 40

. Don’t operate it where the temperature is higher than this. 

 

Don’t connect the device to any dimmer pack. 

 

First run, there will be smoke or smells, and all disappearing a few minutes later. 

 

Make sure there are no flammable materials close to the unit while operating, as it is fire hazard. 

 

Look over power wires carefully, replace immediately if there is any damage. 

 

Unit surface temperature may reach up to 60

. Don’t touch the housing bare-hand during its operation. 

 

Never run on for a long time lest shortening lifespan. 

 

Avoid  any  inflammable  liquids  or  metal  objects  entering  the  unit.  Once  it  happen,  cut  off  the  mains  power 
immediately. 

 

The fixtures must be cleaned regularly if they are in a dirty and dusty environment 

 

Do not allow children to operate the fixture. 

 

Do not touch any wire during operation as there might be a hazard of electric shock. 

 

Avoid power wires together arounding other cables. 

 

Replace fuse only with the same type. 

 

In the event of serious operating problem, stop using the unit immediately. 

 

Never turn on and off the unit time after time. 

 

Do not open the unit as there are no user serviceable parts inside. Never try to repair the unit by yourself. Repairs 
carried  out  by  unskilled  people  can  lead  to  damage  or  malfunction.  Please  contact  the  nearest  authorized 
technical assistance center.  

 

Disconnect the mains power if the fixture is not used for a long time. 

 

Do use original packing materials once transport it again. 

 

Do not look directly at the LED light beam while the fixture is on. 

 

Installation  

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid 
vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure 
and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times 
of the weight of the unit when installing the fixture.  
The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people 
and has no one pass by or under it. 

 

Please read the instructions carefully which includes important 

information about the installation, operation and maintenance. 

Summary of Contents for PAR LED 1418 Z IP

Page 1: ...PAR LED 1418 Z IP NOTICE D UTILISATION...

Page 2: ...ara tre au bout de 15 minutes environ Assurez vous qu il n y ait pas de produits inflammables c t de l appareil afin d viter tout risque de feu Surveillez r guli rement le cordon d alimentation S il e...

Page 3: ...re faite par des professionnels Assurez que votre installation soit hors de port e de toute personne et qu elle ne g ne en aucun cas le passage 1 CARACTERISTIQUES TECHNIQUES PAR LED 14x18W ZOOM IP65 L...

Page 4: ...vert 100 Bleu 100 201 205 Blanc 1 3200K 206 210 Blanc 2 3400K 211 215 Blanc 3 4200K 216 220 Blanc 4 4900K 221 225 Blanc 5 5600K 226 230 Blanc 6 5900K 231 235 Blanc 7 6500K 236 240 Blanc 8 7200K 241 24...

Page 5: ...uction 1 Dimmer 0 255 0 255 2 Rouge 0 255 0 255 3 Vert 0 255 0 255 4 Bleu 0 255 0 255 5 ZOOM 0 255 0 255 MODE ARC 2 7 CAN Fonction Valeur DMX Instruction 1 Rouge 0 255 0 255 2 Vert 0 255 0 255 3 Bleu...

Page 6: ...5 HUE 0 100 2 SATURATION 0 255 SATURATION 0 100 3 VALEUR 0 255 VALEUR 0 100 3 INSTRUCTION POUR L ECRAN AFFICHAGE Menu MODE pour s lectionner les fonctions ou retourner une fonction pr c dente UP pour...

Page 7: ......

Page 8: ...ivant Le c ble ne doit pas tre branch un c ble en Y Des c bles inappropri s ou endommag s des joints soud s ou des connecteurs rouill s peuvent facilement tre l origine de la d formation du signal et...

Page 9: ...es avec le signal DMX mais de fa on intermittente v rifiez les connecteurs ou la carte lectronique de l appareil d faillant ainsi que de l appareil pr c dent 4 Essayer d utiliser un autre contr leur D...

Page 10: ...PAR LED 1418 Z IP USER MANUAL...

Page 11: ...appen cut off the mains power immediately The fixtures must be cleaned regularly if they are in a dirty and dusty environment Do not allow children to operate the fixture Do not touch any wire during...

Page 12: ...Operation mode Auto DMX Master Slave musical Dimming 0 100 Strobe 0 20Hz Beam angle 8 45 Consumption 270W Power supply AC100 240V 50 60Hz Housing Die casting aluminum powder coated finish Dimensions...

Page 13: ...10 0 131 150 Red 100 Green 0 Blue DOWN 151 170 Red 100 Green UP Blue UP 171 190 Red DOWN Green DOWN Blue 100 191 200 Red 100 Green 100 Blue 100 201 205 WHITE1 3200K 206 210 WHITE2 3400K 211 215 WHITE3...

Page 14: ...1 Red 0 255 0 255 2 Green 0 255 0 255 3 Blue 0 255 0 255 4 ZOOM 0 255 0 255 AR1 D MODE 5CH Function DMX Value Instruction 1 Dimmer 0 255 0 255 2 Red 0 255 0 255 3 Green 0 255 0 255 4 Blue 0 255 0 255...

Page 15: ...0 100 2 SATURATION 0 255 SATURATION 0 100 3 VALUE 0 255 VALUE 0 100 3 Display Panel Operation 3 1 Display panel menu instruction MODE menu selection or return to previous menu UP press UP through the...

Page 16: ......

Page 17: ...gh speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system The DMX output and input connectors are pass through to maint...

Page 18: ...X signal problems check the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables...

Reviews: